Table 9. Events that automatically notify Support (continued)
Event ID
Message String
Automatically
Notify Support
806f010c-2581ffff
Uncorrectable error detected for
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName].
Yes
806f010d-0400ffff
The Drive Drive 0 has been disabled due to a detected
fault.
Yes
806f010d-0401ffff
The Drive Drive 1 has been disabled due to a detected
fault.
Yes
806f010d-0402ffff
The Drive Drive 2 has been disabled due to a detected
fault.
Yes
806f010d-0403ffff
The Drive Drive 3 has been disabled due to a detected
fault.
Yes
806f010d-0404ffff
The Drive Drive 4 has been disabled due to a detected
fault.
Yes
806f010d-0405ffff
The Drive Drive 5 has been disabled due to a detected
fault.
Yes
806f010d-0406ffff
The Drive Drive 6 has been disabled due to a detected
fault.
Yes
806f010d-0407ffff
The Drive Drive 7 has been disabled due to a detected
fault.
Yes
806f011b-0c01ffff
The connector LightPath has encountered a configuration
error.
Yes
806f0207-0301ffff
CPU 1 has Failed with FRB1/BIST condition.
Yes
806f0207-0302ffff
CPU 2 has Failed with FRB1/BIST condition.
Yes
806f0207-2584ffff
[ProcessorElementName] has Failed with FRB1/BIST
condition.
Yes
806f020d-0400ffff
Failure Predicted on drive Drive 0 for array
[ComputerSystemElementName].
Yes
806f020d-0401ffff
Failure Predicted on drive Drive 1 for array
[ComputerSystemElementName].
Yes
806f020d-0402ffff
Failure Predicted on drive Drive 2 for array
[ComputerSystemElementName].
Yes
806f020d-0403ffff
Failure Predicted on drive Drive 3 for array
[ComputerSystemElementName].
Yes
806f020d-0404ffff
Failure Predicted on drive Drive 4 for array
[ComputerSystemElementName].
Yes
806f020d-0405ffff
Failure Predicted on drive Drive 5 for array
[ComputerSystemElementName].
Yes
806f020d-0406ffff
Failure Predicted on drive Drive 6 for array
[ComputerSystemElementName].
Yes
806f020d-0407ffff
Failure Predicted on drive Drive 7 for array
[ComputerSystemElementName].
Yes
806f050c-2001ffff
Memory Logging Limit Reached for DIMM 1 on
Subsystem [MemoryElementName].
Yes
806f050c-2002ffff
Memory Logging Limit Reached for DIMM 2 on
Subsystem [MemoryElementName].
Yes
226
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......