background image

 

 

NEC Express5800/T110j-S 
System Configuration Guide

 

 

   

 

 

Introduction 

This document contains product and configuration information that will enable you to configure your system. The guide will 
ensure fast and proper configuration of your NEC Express5800 server. 

December 28, 2018 
Revision 1.0 
NEC Corporation 

Summary of Contents for Express5800/T110j-S

Page 1: ...e Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server December 28 2018 Revision 1 0 NEC Corporation ...

Page 2: ...RDX Drives 22 7 1 RDX Drive 22 7 2 RDX Data Cartridge 22 8 PCI Card 23 8 1 Network Interface Controller 23 8 2 SAS Controller 24 8 3 Serial Port Adapter 24 8 4 NeoFace Accelarator 24 9 Other Add in Components 25 9 1 Internal Battery Kit 25 9 2 High Temperature Support Option 26 9 3 Additional FAN kit for PCI 26 10 Add on Components 26 10 1 Input Device 26 10 2 Server Management License 26 10 3 Dus...

Page 3: ...7M 2 Interfaces 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 4 USB 3 0 2 front 2 rear plus 1 internal USB 3 0 2 USB 3 1 2 rear 2 1000BASE T LAN connector RJ 45 2 rear 1 1000BASE T LAN connector for Management RJ 45 1 rear Server Management Aspeed AST2500 System Fan Standard Power Supply 1 x 250 Watt 80 PLUS Platinum certified non hot plug PSU 2 x 460 Watt 80 PL...

Page 4: ...x8 connector Video Controller VRAM Integrated in Server Management Controller 32MB Resolution Color 1600 x 1200 16 7M 2 Interfaces 1 VGA 15 pin mini D sub 1 rear 1 to 2 Serial 9 pin mini D sub RS232 C 1 to 2 rear 4 USB 3 0 2 front 2 rear plus 1 internal USB 3 0 2 USB 3 1 2 rear 2 1000BASE T LAN connector RJ 45 2 rear 1 1000BASE T LAN connector for Management RJ 45 1 rear Server Management Aspeed A...

Page 5: ...n 1 0 December 2018 5 2 Maximum resolution available via Aspeed AST2500 remote console is 1280 x 1024 65K colors 3 Noise emission was measured in accordance with ISO 7779 at 25 C The actual value may vary by the operating environment 4 Support on Xeon processor systems only ...

Page 6: ...ews Front View Legend A Power Button H Global LED 1 B Dump NMI Button I Global LED 2 C BMC Reset Button J USB 3 0 Connectors D Power LED K Optical Disk Drive E Power Capping LED L Cover Key 2 5 inch Drive Configuration F STATUS LED 1 M Drive Bay Cover G STATUS LED 2 N Stabilizer J A K L M N F D B H C E G I ...

Page 7: ... Revision 1 0 December 2018 7 Rear Views Fixed power supply model Redundant power supply model Legend A Serial Port Connector E Data LAN Connectors B VGA Connector F PCI Slots C USB Connectors G AC Inlet D Management LAN Connector H Power Supply Unit F D C B A E G H ...

Page 8: ... CONFIGRATION GUIDE NEC Express5800 T110j S NEC Corporation Revision 1 0 December 2018 8 Dimensions mm Standard Bezel Tower Orientation Desktop Orientation 395 4 98 0 200 0 347 1 386 5 347 1 386 5 395 4 104 2 ...

Page 9: ...T110j S NEC Corporation Revision 1 0 December 2018 9 Tower Orientation Redundant power supply Desktop Orientation Redundant power supply Dust Proof Bezel Tower Orientation Fixed power supply 447 5 98 0 200 0 347 1 415 7 347 1 415 7 447 5 104 2 ...

Page 10: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110j S NEC Corporation Revision 1 0 December 2018 10 Desktop Orientation Fixed power supply 415 7 98 0 200 0 347 1 423 7 347 1 415 7 423 7 104 2 ...

Page 11: ...TION GUIDE NEC Express5800 T110j S NEC Corporation Revision 1 0 December 2018 11 Tower Orientation Redundant power supply Desktop Orientation Redundant power supply 447 5 98 0 200 0 347 1 415 7 347 1 415 7 447 5 104 2 ...

Page 12: ...ress5800 T110j S NEC Corporation Revision 1 0 December 2018 12 Configuration Diagram Fixed Power Supply Model Legend Standard Components Mandatory Components Redundant Power Supply Model Legend Standard Components Mandatory Components ...

Page 13: ...018 13 Expansion Slots Legend 1 PCIe 3 0 x4 x8 connector Low Profile up to 168mm length 2 PCIe 3 0 x4 x8 connector Low Profile up to 168mm length 3 PCIe 3 0 x16 x16 connector Low Profile up to 168mm length 4 PCIe 3 0 x4 x8 connector Low Profile up to 168mm length Slot 4 Slot 3 Slot 2 Slot 1 ...

Page 14: ... Kit Intel Xeon Processor E 2124 3 3 GHz 4C 4T 8 MB N8101 1467F Xeon E 2124G Processor Kit Intel Xeon Processor E 2124G 3 4 GHz 4C 4T 8 MB N8101 1468F Xeon E 2126G Processor Kit Intel Xeon Processor E 2126G 3 3 GHz 6C 6T 12 MB N8101 1469F Xeon E 2134 Processor Kit Intel Xeon Processor E 2134 3 5 GHz 4C 8T 8 MB N8101 1470F Xeon E 2146G Processor Kit Intel Xeon Processor E 2146G 3 5 GHz 6C 12T 12 MB...

Page 15: ...r the maximum memory size that you can actually use on your system Operating Systems Maximum Memory Size Supported by Operating Systems Maximum Available Memory Microsoft Windows Server 2016 Standard 1 Microsoft Windows Server 2016 Datacenter 1 24TB 64GB 1 The maximum available memory size of Hyper V systems is below Windows Server 2016 24 TB ...

Page 16: ...S SATA drive 2 5 inch Drive The 4x 2 5 inch drive cage can mount four 2 5 inch SAS SATA drives as standard For installing more drives please add an additional drive cage One cables is attached in drive cage for connection to maximum of four SAS SATA drives 3 5 inch Drive The 2x 3 5 inch drive cage can install two 3 5 inch SATA drives as standard For installing more drives please add an additional ...

Page 17: ...rnal RDX drive cannot be installed in the redundant power supply model with optional 2 5 inch drive cage Hot plug insertion removal of any drive is not supported when both 3 5 inch and 2 5 inch drives are installed When N8154 83F 2 5 Inch Hot Plug Drive Cage Kit is installed ambient temperature is up to 40 C N8181 140F High Temperature Support Option is not supported Internal RDX drive cannot be i...

Page 18: ...drive cage Attached in Cage NOTE All hard drives within a RAID array should be of the same capacity and rotation speed Embedded SATA RAID controller is supported only on limited OS For more details please see OS Support Matrix for PCI Cards and Embedded Controllers Embedded SATA controller support on Windows only Up to two kinds of drives selected from SAS 10K HDDs 512n SAS 10K HDDs 512e SAS 15K H...

Page 19: ...ed All drives within a RAID array should be of the same capacity and rotation speed Up to two kinds of drives selected from SAS 10K HDDs 512n SAS 10K HDDs 512e SAS 15K HDDs SATA HDDs and SSDs can be mixed in a system However SAS HDDs and SATA HDDs cannot be mixed in the same cage and HDDs in the same cage must have the same rotational speed To configure a large capacity RAID array it is recommende...

Page 20: ...DD 1x 900 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512e sector NOTE It can not be supported when install N8146 74 Dust Proof Bezel N8150 586 SAS SSD eMLC 200GB Hot Plug 2 5 inch SAS SSD 1 x 200 GB SAS SSD eMLC 2 5 inch 12Gb s 512n sector N8150 721 400GB Hot Plug 2 5 inch SAS SSD 1 x 400 GB SAS SSD eMLC 2 5 inch 12Gb s 512n sector N8150 722 NOTE Hot plug insertion removal is not supported with the emb...

Page 21: ...only N8103 205 206 210 is supported with VMware When installing M 2 SATA SSD only Embedded SATA controller or N8103 205 206 210 is supported with Windows Mixed installation of M 2 SATA SSD and SSD HDD is supported on Embedded SATA controller Up to two M 2 SSDs can be mounted on M 2 installation kit two M 2 SSDs are required the same capacity 5 Internal Optical Drive Category Product Name Descripti...

Page 22: ...on bay 2 When internal simple UPS is installed internal RDX is supported in 3 5 inch expansion bay 1 In redundant PSU model internal RDX is supported in 3 5 inch expansion bay 1 One of 2 5 inch Drive Cage or RDX is supported in 3 5 inch expansion bay 1 Ambient temperature is up to 40 C N8181 140F High Temperature Support Option is not supported RDX is not supported for VMware 7 2 RDX Data Cartridg...

Page 23: ...dapter N8104 157 SFP Module SFP Module 10G SR 1 x SFP Module N8104 129 NOTE The system includes 2x 1000BASE T LAN ports by default NIC Teaming feature NIC Teaming and bonding features The Express5800 server supports NIC teaming which is the ability to configure multiple NICs to virtual single network interface for dual path and load balancing to fault tolerance and load balancing Network Load Bala...

Page 24: ...figuration Guide for supported SAS cable Up to one SAS controller can be installed 8 3 Serial Port Adapter Product Name Description Part Number Serial Port Adapter Serial port fixed to PCI bracket N8117 01A NOTE Up to one Serial Port Adapter can be installed 8 4 NeoFace Accelarator Product Name Description Part Number NeoFace Accelerator NeoFace Accelerator PCIe 3 0 x8 with cover N8105 52 NOTE Up ...

Page 25: ...p to one unit per system Ambient temperature is up to 40 C N8181 140F High Temperature Support Option is not supported When internal simple UPS and N8154 82F 2 5 inch Drive Cage are installed N8154 83F 2 5 Inch Hot Plug Drive Cage Kit is not supported When internal simple UPS is installed HDD SSD is only support up to 4 System Power Battery Discharging Time 50W 930 sec 75W 620 sec 100W 450 sec 125...

Page 26: ...tion Only support on redundant PSU model N8181 172 Note This product is used for cooling of N8105 52 NeoFace Accelerator In order to ensure sufficient cooling effect cooling fan rotate higher speed and it makes system acoustic noise become high This is the specification of this product and it doesn t influence system operation PCI slot2 can t be installed with any PCI cards Option that can t be su...

Page 27: ...ter 5 pcs For Dust Proof filter Removal capacity of particles Up to 1 μm sized N8147 36 NOTE When Dust Proof Bezel is installed N8150 586 900GB 15K Hot Plug 2 5 inch SAS HDD can not be supported N8105 52 NeoFace Accelerator or N8181 172 Additional FAN kit for PCI can not be supported 10 4 Tamper Proof Power Button Covers Product Name Description Part Number Tamper Proof Cover For Standard Bezel Ta...

Page 28: ...P Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Remote batch No UPS required ESMPRO SM required 6 6 Others Set automatic IP address via DNS DHCP LDAP Active Directory verification user control Clock synchronization of main unit and the RTC 5 5 Access log collection IPv6 Remote control via Web browser DMTF compliant CLP only Industry Standard ...

Page 29: ... N8103 205 RAID Controller 2GB RAID 0 1 5 6 1 N8103 206 RAID Controller 2GB RAID 0 1 WT WB 1 N8103 207 RAID Controller 2GB RAID 0 1 5 6 WT WB 1 N8103 208 RAID Controller 4GB RAID 0 1 5 6 1 N8103 210 RAID Controller 2GB RAID 0 1 WT 1 N8103 211 RAID Controller 2GB RAID 0 1 5 6 WT 1 N8105 52 NeoFace Accelerator 1 N8104 157 Dual Port 10GBASE T Adapter 4 1 3 1 1 1 2 N8104 149 10GBASE SFP Adapter SFP 2c...

Page 30: ...t is disabled Keep the setting disabled to use other operating systems and or software Supported OS and Software for Secure Boot Mode Operating System Supported Boot Mode Secure Boot Mode Windows Server 2016 UEFI Software Related to Boot Supported Boot Mode Secure Boot Mode System Diagnostics Utility UEFI EXPRESSBUILDER UEFI Supported Boot Device for Secure Boot Mode Supported Boot Device Part Num...

Page 31: ... trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial errors or o...

Page 32: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110j S NEC Corporation Revision 1 0 December 2018 32 Revision History Revision Date Description 1 0 December 28 2017 Initial release ...