Other Add-in Components
9.1
Internal Battery Kit
Product Name / Description
Part Number
Internal simple UPS Control Kit
Internal simple UPS controller
3.5-inch expansion bay(2) support
N8181-153
Internal simple uninterrupted power supply
Internal simple UPS unit
3.5-inch expansion bay(2) support
N8181-152
NOTE:
Only support on fixed PSU model
Only support up to one unit per system
Ambient temperature is up to 40
°C.N8181-140F. High Temperature Support Option is not supported.
When internal simple UPS and N8154-82F 2.5-inch Drive Cage are installed, N8154-83F 2.5-Inch Hot Plug Drive Cage Kit is not
supported.
When internal simple UPS is installed, HDD/SSD is only support up to 4.
System Power
Battery Discharging Time
50W
930 sec.
75W
620 sec.
100W
450 sec.
125W
330 sec.
150W
240 sec.
175W
210 sec.
200W
180 sec.
NOTE:
The above discharging time is a reference value at full charge. Actual battery supply time varies by the operational environment