Explanation:
Current Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Reboot the system. Will come up on backup UEFI image. Update the primary UEFI image.
2. If error does not persist no additional recovery action is required.
3. If error persists, or boot is unsuccessful, replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
I.3818002 [I.3818002] The firmware image capsule signature for the non-booted flash bank is
invalid.
Explanation:
Opposite Bank CRTM Capsule Update Signature Invalid
Severity
Info
User Response
Complete the following steps:
1. Update the backup UEFI image.
2. If error does not persist, no additional recovery action is required.
3. If error persists, or boot is unsuccessful, replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
I.3818003 [I.3818003] The CRTM flash driver could not lock the secure flash region.
Explanation:
CRTM Could not lock secure flash region
Severity
Info
User Response
Complete the following steps:
1. If system failed to boot successfully, DC cycle the system.
2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, replace the system board.
Related links
593
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...