4. Reset the CMM to factory defaults and attempt to discover the nodes again. Allow enough time for the
IMMs to acquire a network address.
5. Replace the CMM.
6. Make sure that the IMM in the compute node has acquired an IP address from the CMM by using
the Setup utility on the node.
Note:
If the CMM recently lost connection to the DCHP server, you must reset the IMM by using the
CMM interface so that a new IP address can be acquired.
7. In the CMM user interface, click
Chassis Management > Component IP Configuration
and make
sure that the IP address that is listed is the same as the IP address that is displayed in the Setup
utility. If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to
automatically acquire a new IP address.
8. Check http://www.lenovo.com/support for any firmware updates that might apply to this problem. You
can view the release notes for a firmware update to determine the issues that the update addresses.
9. Remove the compute node from the chassis and check the connectors on the back of the node for
bent pins. If the pins are bent, contact Support.
10. Check http://www.lenovo.com/support for any service bulletins that are related to network connectivity.
11. (Trained service technician only) Complete the following steps:
a. Force the link/duplex speed.
b. Check the connectors on the CMM to make sure that no pins are bent.
c. Check the connectors on the chassis midplane to make sure that no pins are bent.
d. Remove the CMM and install a working CMM in the same bay.
e. If the problem is solved, replace the CMM that you removed.
CMM cannot ping the CMM in a different chassis
Use the information in this section to troubleshoot a CMM that cannot ping the CMM in a different chassis.
Complete the following steps until the problem is solved:
1. Make sure that the Chassis Management Modules are powered on and the applicable ports are enabled.
a. If the CMM is powered on and hung, reset the CMM.
b. Make sure that the IMM, the management node, and the CMMs are all on the same subnet.
2. Verify that the cables between the CMMs and the top-of-rack switch are correctly connected and that
the activity LEDs are lit on the applicable ports.
3. Make sure that the management node has a correct IP address and is on the same subnet as the CMMs.
4. Make sure that the IMM in the compute node has acquired an IP address from the CMM by using
the Setup utility on the node.
Note:
If the CMM recently lost connection to the DCHP server, you must reset the IMM by using the
CMM interface so that a new IP address can be acquired.
5. In the CMM user interface, click
Chassis Management > Component IP Configuration
and make
sure that the IP address that is listed is the same as the IP address that is displayed in the Setup
utility. If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to
automatically acquire a new IP address.
6. Check http://www.lenovo.com/support for any firmware updates that might apply to this problem. You
can view the release notes for a firmware update to determine the issues that the update addresses.
7. Check http://www.lenovo.com/support for any service bulletins that are related to network connectivity.
620
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...