Step 1.
Remove the cover (see “Removing the compute node cover” on page 643).
Step 2.
Remove the air baffle installed over the DIMM connector.
000
000
000
000
000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Right
air baffle
Left
air baffle
Step 3.
Locate the DIMM connectors (see “System-board connectors” on page 17). Determine which
DIMM you want to remove from the compute node.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connectors, handle the
clips gently.
Step 4.
Make sure that both retaining clips on the DIMM connector from which you are removing the
DIMM are in the open position.
Step 5.
Pull the DIMM out of the connector.
Step 6.
If you are not immediately replacing the DIMM, install the air baffle.
Attention:
To maintain proper system cooling, do not operate the compute node without air
baffles installed over the DIMM connectors.
If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging materials
for shipping that are supplied to you.
Installing, removing, and replacing compute node components
653
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...