2. Make sure that the Flex System Manager management node or the CMM can ping the compute nodes.
If it cannot, see “Cannot ping the Flex System Manager management node on the management
network” on page 625.
3. If the compute nodes are in another chassis, make sure that you have the necessary software
entitlements to manage that chassis with the Flex System Manager management node.
4. Check http://www.lenovo.com/support for any firmware updates that might apply to this issue. You can
view the release notes for a firmware update to determine the issues that are addressed by the update.
5. Check http://www.lenovo.com/support for any service bulletins that are related to network connectivity.
Collecting service data
The first-failure data capture (FFDA) tool monitors, tracks, and captures system hardware errors and
hardware and software inventory information, and reports serviceable problems directly to Support. You can
also choose to collect data manually. This tool is integrated into the IMM2. All information that is sent to is
encrypted and stored in a secure database and used for improved problem determination.
For more information about accessing the IMM2, see Chapter 4 “Accessing the IMM2” on page 47.
635
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...