Chapter 17 Troubleshooting
17-29
F
84A7
Application
error
DTR Signal timeout error
1.
Check for disconnected connectors of
communication cable between main ? mechanical
control (control board side, mechanical control side)
2.
Check communication cable between main ?
mechanical control for broken wires
3.
Replace cables between main mechanical control
4.
Replace the mechanical control board
5.
After replacing the control box, restore the settings
F
84A8
Application
error
Mechanical control initial data
notification
Timeout error
F
84B0
Application
error
COM4 open failed
After replacing the control box, restore the settings
F
84B1
Application
error
Acquisition of communication port initial
value failed
F
84B2
Application
error
Input Baud rate settings failed
F
84B3
Application
error
Output Baud rate settings failed
F
84B4
Application
error
Other Rs232c settings failed
F
84C0
Application
error
Update process error file open failed
F
84C1
Application
error
Update process error file read failed
C
8600
Caution
Reception socket error:
NetIF_WatchStatus function select error
C
8602
Caution
Reception from main failed: Error
occurred in ReceiveProcMsg function
C
8604
Caution
Data section reception from PC failed:
Error occurred in Receive function
1.
Check condition of network communication with
PrintLink5-IN (CS-2)
2.
Replace HUB, network cables Replace HUB,
network cables
3.
After replacing the control box, restore the settings
D
8605
Caution
Header section reception from PC failed:
Error occurred in Receive function
1.
Check condition of network communication with
PrintLink5-IN (CS-2)
2.
Replace HUB, network cables Replace HUB,
network cables
C
8606
Caution
Send to PC failed: Error occurred in
common Send function
1.
Check condition of network communication with
PrintLink5-IN (CS-2)
。
2.
Replace HUB, network cables Replace HUB,
network cables
。
3.
After replacing the control box, restore the settings
。
C
8607
Caution
Send to main control failed: Error
occurred in common SendProcMsg
function
After replacing the control box, restore the settings
F
8608
Application
error
PC access wait failed:
Error occurred in WaitConnect function
1.
Check condition of network communication with
PrintLink5-IN (CS-2)
2.
Replace HUB, network cables Replace HUB,
network cables
3.
After replacing the control box, restore the settings
F
8609
Application
error
Port open for PC reception failed: Error
occurred in OpenServer function
After replacing the control box, restore the settings
F
860A
Application
error
Thread creation failed: Error occurred in
pthread_create function
F
860B
Application
error
Update file obtain request was not sent.
1.
Check condition of network communication with
PrintLink5-IN (CS-2)
2.
Replace HUB, network cables Replace HUB,
network cables
3.
After replacing the control box, restore the settings
C
8640
Caution
Receive data from PC
sending source process name is incorrect
C
8641
Caution
Receive data from main
sending source process name is incorrect
After replacing the control box, restore the settings
Error
Level
Error
Code
Error
Message (Display
Characters)
Error contents
Error Support: Service
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......