Chapter 5 Replacing Tray Unit Loading Parts
5-9
14
Connect the connector removed in
step 5
.
•
If the tray unit elevating plate HP sensor has been replaced, connect the connector (JP56).
•
If the Lispl-832 elevating plate HP sensor has been replaced, connect the connector (JP64).
15
Install the rear cover or the back cover.
•
If the tray unit elevating plate HP sensor has been replaced, refer to
“
Installation Procedure (Page 3-19)”
in
“3.3.4 Removing/Installing Rear Cover”
and then attach the rear cover.
•
If the Lispl-832 elevating plate HP sensor has been replaced, refer to
“
Installation Procedure (Page 3-21)”
in
“3.3.5 Removing/Installing Rear Cover (Lispl-832)”
and then attach the back cover.
16
Return the supply tray and tray shutter to their original positions.
This is the end of the process of replacing the elevating plate HP sensor.
Caution
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
an odor may be generated.
Caution
Take sufficient care when handling the tray shutter, as it may be impossible to insert if it
becomes deformed due to rough handling.