Chapter 17 Troubleshooting
17-25
F
4B34
Note the error
code and make
a request for
servicing
An error occurred reading FLASH.
Replace mechanical control board
F
4B35
Note the error
code and make
a request for
servicing
CN5 on the mechanical control is
disconnected. LCD connector
disconnected
Due to the F error, switch the power OFF (shutdown
operations), and reconnected the mechanical control
connector CN5 with the LCD board connector CN1.
F
4B36
Note the error
code and make
a request for
servicing
CN25 on the mechanical control is
disconnected. HPRO temperature sensor
connector disconnected
Due to the F error, switch the power OFF (shutdown
operations), and reconnected the mechanical control
connector CN25 with the HPRO unit relay connector.
F
4B37
Note the error
code and make
a request for
servicing
CN15 on the mechanical control is
disconnected. H-DRV Board connector
disconnected
Due to the F error, switch the power OFF (shutdown
operations), and reconnected the mechanical control
connector CN15 with the LCD board connector CN6.
F
4B38
Note the error
code and make
a request for
servicing
CN22 on the mechanical control is
disconnected. Internal temperature sensor
connector disconnected
Due to the F error, switch the power OFF (shutdown
operations), and reconnected the mechanical control
connector CN22.
F
4B39
Note the error
code and make
a request for
servicing
CN16 on the mechanical control is
disconnected. Or the HPRO motor is not
operating.
•
Due to the F error, switch the power OFF (shutdown
operations), and reconnected the mechanical control
connector CN16.
•
Replace the HPRO motor
F
4F00
Control error
Operation unit response timeout error
Due to the F error, switch the power OFF/ON.
F
8000
Application
error
Parameter error
After replacing the control box, restore the settings
F
8001
Application
error
File does not exist.
F
8003
Application
error
MOT file is not stored in the heap,
address error.
F
8004
Application
error
Error in MOT file syntax, midway
address error
F
8005
Application
error
Reading error in MOT file
F
8006
Application
error
Data error in ini file
E
8007
Application
error
Received data error
1.
Replace the mechanical control board
2.
After replacing the control box, restore the settings
E
8008
Application
error
Sent data error
F
8009
Application
error
Insufficient memory
After replacing the control box, restore the settings
F
800A
Application
error
Communication device open error
F
800B
Application
error
Communication timeout
1.
Check for disconnected connectors of
communication cable between main-mechanical
control (control board side, mechanical control side)
2.
Check communication cable between main-
mechanical control for broken wires
3.
Replace cables between main-mechanical control
4.
Replace the mechanical control board
5.
After replacing the control box, restore the settings
F
800C
Application
error
Mechanical control DSR does not switch
ON, or does not switch OFF
F
800E
Application
error
Mechanical control rebooted
(1A reception recognized 3 times).
F
800F
Application
error
Cannot send 1B to mechanical control.
After replacing the control box, restore the settings
Error
Level
Error
Code
Error
Message (Display
Characters)
Error contents
Error Support: Service
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......