Chapter 17 Troubleshooting
17-16
E
3024
Temperature
error
Irrespective of the status of the machine,
check the temperature of heating F every
1 second, and if the temperature is
continually 147
°
C for 5 seconds, an error
occurs
1.
Check HPRO OFFSET and mechanical control offset
2.
Check the connection between the H-DRVboard and
mechanical control board
3.
Check connection between mechanical control
board and HPRO unit
4.
Check conductance of the power cable
5.
Check voltage
6.
Replace H-DRV board
7.
Replace heat process unit
8.
Replace mechanical control board
9.
Replace the wire bundle between the H-DRVboard
and mechanical control board
10.
Replace wire bundle between mechanical control
board and HPRO unit
E
3032
Temperature
error
When the heating temperature C1 30
second moving average temperature is
compared to 130
°
C, an error occurs when
the temperature is 5
°
C higher when
Ready and 10
°
C higher when in PRINT.
E
3033
Temperature
error
When the heating temperature C1 30
second moving average temperature is
compared to 130
°
C, an error occurs when
the temperature is 5
°
C lower when Ready
and 10
°
C lower when in PRINT.
1.
Check HPRO OFFSET and mechanical control offset
2.
Check whether the short-circuit breaker (domestic)
or circuit protector (domestic) is OFF
3.
Check the connection between the H-DRVboard and
mechanical control board
4.
Check connection between mechanical control
board and HPRO unit
5.
Check conductance of the power cable
6.
Check voltage
7.
Replace H-DRV board
8.
Replace heat process unit
9.
Replace mechanical control board
10.
Replace the wire bundle between the H-DRVboard
and mechanical control board
11.
Replace wire bundle between mechanical control
board and HPRO unit
E
3034
Temperature
error
Irrespective of the status of the machine,
check the temperature of heating C1
every 1 second, and if the temperature is
continually 147
°
C for 5 seconds, an error
occurs
1.
Check HPRO OFFSET and mechanical control offset
2.
Check the connection between the H-DRVboard and
mechanical control board
3.
Check connection between mechanical control
board and HPRO unit
4.
Check conductance of the power cable
5.
Check voltage
6.
Replace H-DRV board
7.
Replace heat process unit
8.
Replace mechanical control board
9.
Replace the wire bundle between the H-DRVboard
and mechanical control board
10.
Replace wire bundle between mechanical control
board and HPRO unit
E
3042
Temperature
error
When the heating temperature C2 30
second moving average temperature is
compared to 130
°
C, an error occurs when
the temperature is 5
°
C higher when
Ready and 10
°
C higher when in PRINT.
1.
Check HPRO OFFSET and mechanical control offset
2.
Check the connection between the H-DRVboard and
mechanical control board
3.
Check connection between mechanical control
board and HPRO unit
4.
Check conductance of the power cable
5.
Check voltage
6.
Replace H-DRV board
7.
Replace heat process unit
8.
Replace mechanical control board
9.
Replace the wire bundle between the H-DRVboard
and mechanical control board
10.
Replace wire bundle between mechanical control
board and HPRO unit
E
3043
Temperature
error
When the heating temperature C2 30
second moving average temperature is
compared to 130
°
C, an error occurs when
the temperature is 5
°
C lower when Ready
and 10
°
C lower when in PRINT.
1.
Check HPRO OFFSET and mechanical control offset
2.
Check whether the short-circuit breaker (domestic)
or circuit protector (domestic) is OFF
3.
Check the connection between the H-DRVboard and
mechanical control board
4.
Check connection between mechanical control
board and HPRO unit
5.
Check conductance of the power cable
6.
Check voltage
7.
Replace H-DRV board
8.
Replace heat process unit
9.
Replace mechanical control board
10.
Replace the wire bundle between the H-DRVboard
and mechanical control board
11.
Replace wire bundle between mechanical control
board and HPRO unit
Error
Level
Error
Code
Error
Message (Display
Characters)
Error contents
Error Support: Service
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......