Chapter 14 Setting and Adjustment
14-10
17
Measure the center of each patch in the <3> row of the printed ST13C PATTERN, using the
densitometer.
Write down the measurement result on the film as a base value.
18
Observe the center of each patch in the <1> row of the printed ST13C PATTERN, using the
densitometer, and determine the number (OFFSET) nearest to the base value measured in
step 17
of the patches from (01) to (13).
Write down the number (OFFSET) determined on the film.
Note
•
The number to be determined here is the one that is attached to each density patch in the ST13C test
pattern.
•
Compare the measured result of the <1> row with the standard value of the same number of the <3>
row.
Summary of Contents for Drypro 832