Chapter 5 Replacing Tray Unit Loading Parts
5-19
17
Install the cover removed in
step 8
.
• Two screws (M3
×
6)
18
Install the bracket removed in
step 6
.
• One screw (M3
×
6)
Hook the notch of the bracket onto the notch of the main unit
to attach.
19
Connect the connector removed in
step 5
.
•
If the tray unit tray detection sensor has been replaced, connect the connectors (JP56).
•
If the Lispl-832 tray detection sensor has been replaced, connect the connector (JP64).
20
Install the rear cover.
•
If the tray unit tray detection sensor has been replaced, refer to
“
Installation Procedure (Page 3-19)”
in
“3.3.4 Removing/Installing Rear Cover”
and attach the rear cover.
•
If the Lispl-832 tray detection sensor has been replaced, refer to
“
Installation Procedure (Page 3-21)”
in
“3.3.5 Removing/Installing Rear Cover (Lispl-832)”
and then attach the back cover.
21
Return the supply tray and tray shutter to their original positions.
This is the end of the process of replacing the tray detection sensor.
Caution
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
an odor may be generated.
Caution
Take sufficient care when handling the tray shutter, as it may be impossible to insert if it
becomes deformed due to rough handling.
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......