Chapter 7 Replacing Sub Scan Unit Loading Parts
7-6
8
Remove the fixing screws of sub scan unit.
• Four screws (M4
×
8)
9
Remove the connectors (JJ15) and (JJ18).
10
Remove wire from the locking wire saddle and
take off the connectors (CCN6) and (JJ25).
11
Remove the ground wire.
• One screw (M4
×
8)
×
2
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Note
Turn the wire disconnected from the connector
toward the main unit to keep out of the way of
the sub scan unit when it is pulled out.
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Note
Turn the wire disconnected from the connector
toward the main unit to keep out of the way of
the sub scan unit when it is pulled out.