Chapter 6 Replacing Lispl-832 (Optional) Loading Parts
6-6
4
Remove the connector (JP64).
5
Remove the supply elevating motor holding
bracket together with the motor.
・
One screw (M3
×
6
)
The bracket is hooked on the notch in the main unit, but can
be unhooked by sliding slightly to the right and pulling back.
6
Remove the connector (JP65).
7
Remove the bracket.
• Four screws (M3
×
6
)
The bracket is hooked on the notch in the main unit, but can
be unhooked by sliding slightly to the right and pulling back.
8
Remove the E ring with a precision screwdriver.
9
Remove the gear.
• Two gears
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Caution
When removing the E ring, be sure not to
exert too much force. Doing so may cause
you to stab your finger with the precision
screwdriver, or may cause the E ring to
spring out and become lost.