Chapter 18 Technical Information
18-18
18.3.7 Noise Filter
CN10
Interlock SW
connector (unused)
Caution
•
When replacing the board, always turn OFF the power source breaker, and remove the
power source plug. If the work is performed while the power plug is connected, there is a
possibility of electric shock.
•
To prevent electric shock, first remove CN1, and then remove the other connectors.
When connecting the connectors, always plug in the CN1 connector last.
•
Always place the removed multiple power source on an insulation material.
If placed on top of a conductor such as metal, there is a possibility of shorting due to residual
voltage.
TP
Application
TP1
AC input tab L side (AC100V - AC240V input)
TP2
AC input tab N side (AC100V - AC240V input)
TP3
Heater AC output tab L side (AC100V - AC240V input)
TP4
Multiple power supply AC output tab L side (AC100V - AC240V input)
TP5
FG tab
TP6
Heater AC output tab N side (AC100V - AC240V input)
TP7
Multiple power supply AC output tab N side (AC100V - AC240V input)
Caution
•
When replacing the board, always turn OFF the power supply breaker, and remove the
power supply plug.If the work is performed while the power plug is connected, there is a
possibility of electric shock.
•
To prevent electric shock, first remove TP1 and TP2, and then remove the other tabs.
When connecting the tabs, always plug in the TP1 and TP2 connector last.
•
Always place the removed noise filter on an insulation material.
If placed on top of a conductor such as metal, there is a possibility of shorting due to
residual voltage.
connector
Application
connector
Application
TP2
TP6
TP1
TP3
TP4
TP7
TP5
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......