Chapter 5 Replacing Tray Unit Loading Parts
5-7
3
Remove the rear cover.
• Six screws (M4
×
8)
Proceed to
step 5
.
4
Remove the rear cover of Lispl-832.
・
Six screws (M4
×
8)
5
Remove the connector.
•
To replace the tray unit elevating plate HP sensor, remove
the connector (JP56).
•
To replace the Lispl-832 elevating plate HP sensor, remove
the connector (JP64).
6
Remove the supply elevating motor holding
bracket together with the motor.
• One screw (M3
×
6)
The bracket is hooked on the notch in the main unit, but can
be unhooked by sliding slightly to the right and pulling back.
7
Remove the connector (JP42).
Note
Remove the upper two screws and the one screw
in the center from the rear cover and loosen the
bottom three.
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.