Chapter 9 Replacing Loading Parts in Heat Process Unit
9-21
4
Remove the connector (JP21).
5
Remove the deodorant fan.
• Four screws (M3
×
30)
6
Install a new deodorant fan.
• Four screws (M3
×
30)
7
Connect the connector (JP21) removed in
step 4
.
8
Install the rear cover with reference to
“
Installation Procedure (Page 3-19)”
in
“3.3.4
Removing/Installing Rear Cover”
.
9
Return the supply tray and tray shutter to their original positions.
This is the end of the process of replacing the deodorant fan.
Caution
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
Caution
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
an odor may be generated.
Caution
Take sufficient care when handling the tray shutter, as it may be impossible to insert if it
becomes deformed due to rough handling.
Summary of Contents for Drypro 832