Chapter 4 Replacing Supply Unit Loading Parts
4-3
4.1.2 Removing/Installing Light Shield Assembly
This section describes the procedure for removing or installing the light shield unit assembly when replacing loading
parts in the light shield unit.
Work outline
The number of personnel and the estimated work hours required to replace load parts is as follows:
Requirements
The procedure for replacing loading parts requires the following tools:
Removal Procedure
1
Pull the tray shutter out of the lower part of the
supply tray.
2
Insert the tray shutter into the slot in the upper
part of the supply tray with the tray shutter's UP
mark on the top surface toward you.
Inserting the tray shutter as far as it will go unlocks and
causes it to pop out several centimeters.
3
Slowly pull out the supply tray fully.
Caution
Be sure to turn off power and remove the power cable from the electrical outlet before removing
or installing the exterior cover or replacing load parts.
Number of
Personnel
Work Hours
1
3 minutes each
No.
Tools
No.
Tools
1
Various types of screwdrivers
2
Tray (container for screws and parts removed)
Caution
•
When replacing loading parts, be sure to
replace with the tray shutter attached.
If some of the film remains on the tray, the
film may be exposed.
•
Take sufficient care when handling the
tray shutter, as it may be impossible to
insert if it becomes deformed due to
rough handling.
•
If you feel any resistance when inserting
the tray shutter, stop the procedure and
refer to
“17.1.7 Pickup malfunction
trouble (Page 17-6)”
to fix the problem.
Caution
Do not place objects on, lean on, or apply
loads on the pulled out supply tray.
Summary of Contents for Drypro 832
Page 2: ......
Page 12: ......
Page 22: ......
Page 28: ......
Page 74: ......
Page 118: ......
Page 228: ......
Page 242: ......
Page 388: ......
Page 498: ......
Page 521: ...18 23 18 5 Block Diagram ...
Page 527: ...18 29 18 7 Printing Operation Load Timing Chart Standard 1 ch ...
Page 529: ......