Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0F2C
Unknown box ID
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2D
Unknown box ID, Code level mismatch.
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2E
SPCN Network Fault
The box ID is not defined. A network communications failure occurred.
TWRCARD
BACKPLN
21F9429
102B
PCC Overcurrent
The power control compartment is causing an over current condition in the
FC 5032 Removable Storage Unit power system.
The ac module and the SPCN port cable should be exchanged together.
TWRCARD
21F5680
21F5793
21F9362
1100
Power Supply P01 error
A fault detection failure occurred for Power Supply P01.
1101
Power Supply P02 error
A fault detection failure occurred for Power Supply P02.
1102
Power Supply P03 error
A fault detection failure occurred for Power Supply P03.
1103
Power Supply P04 error
A fault detection failure occurred for Power Supply P04.
1104
Power Supply P05 error
A fault detection failure occured for Power Supply P05.
1105
Power Supply P06 error
A fault detection failure occured for Power Supply P06.
1108
Regulator R01 error
A fault detection failure occurred for Regulator R01.
1109
Regulator R02 error
A fault detection failure occurred for Regulator R02.
110A
Regulator R03 error
A fault detection failure occurred for Regulator R03.
110B
Regulator R04 error
A fault has been detected for Regulator R04.
1xxx
86
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)