Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
9092
Disk unit requires initialization before use.
Perform SDIOP-PIP26.
9093
Read cache device not in correct format
Contact your next level of support.
B934
Incompatible hardware detected.
FF3D
I/O adapter detected recoverable error
FF6D
I/O processor detected a recoverable system bus error
Table 2. Failing Items Details
Failing Item
Description
Document Description
AJDGP01
I/O processor Licensed Internal Code
Service Functions; APAR or LICTR
ANYBRDG
System I/O bus or any attached card
Problem Analysis; Symbolic FRU Isolation
ANYBUS
IOP card bus error
Problem Analysis; Symbolic FRU Isolation
BACKPLN
Card Enclosure or Planar Board
Problem Analysis; Symbolic FRU Isolation
CACHBAT
Cache battery pack
Problem Analysis; Symbolic FRU Isolation
DEVBPLN
Device backplane
Problem Analysis; Symbolic FRU Isolation
DEVTERM
Terminating plug
Problem Analysis; Symbolic FRU Isolation
IOP
I/O processor card
Problem Analysis; Symbolic FRU Isolation
PCIBUS
Any PCI card on the PCI bus
Problem Analysis; Symbolic FRU Isolation
STORIOA
Storage I/O adapter
Problem Analysis; Symbolic FRU Isolation
SVCDOCS
Customer engineer directed to system problem
analysis
Problem Analysis; Symbolic FRU Isolation
USER
System Operator/User
Problem Analysis; Symbolic FRU Isolation
(2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C,
286D, 286E, 286F, 5702) Reference Codes
1.
If the error is reported on the control panel, the unit reference code is
characters 5 through 8 of the top 16 character line of function 11. If the error is
reported on the console, the unit reference code is the 4 rightmost characters of
word 1.
2.
Find the unit reference code in the following table.
Attention:
The 673x is a read cache. Perform all actions required for 673x as a
disk drive and logic card except where separate 673x cache instructions are
provided.
For more on the Failing Item column entries, see Table 2. Failing Items Details,
which follows the reference code table below.
Table 1. (2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284D, 284E, 286C,
286D, 286E, 286F, 5702) Reference Codes
2748, 2757, 2763, 2778, 2782, 5703
System Reference Codes
145