Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
5311
System LIC program exception occurred
LPAR configuration data does not match current system configuration. The
system will not IPL past DST until the problem is corrected.
Following is a list of problems which may have caused this SRC to be
reported:
v
Non-configured disk unit which was previously a load source on a
partitioned system.
v
Load source configuration data does not match partition for which it is
being used.
v
Load source configuration data does not match system serial number for
which it is being used.
v
Load source configuration data is newer than primary partition
configuration data.
Perform LPAR-PIP01.
5312
System LIC program exception occurred
LPAR configuration data informational error.
The LPAR configuration data was found to be or inconsistent on a
secondary partition’s load source. The data was automatically updated to
the current system level.
5313
System LIC program exception occurred
LPAR configuration data informational error.
The LPAR configuration data was found to be inconsistent on a primary
partition and could only be corrected with an older copy of the data.
5340
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system processor
entries from approximately the same time. Perform the actions indicated
for those entries. For more information on Logical Partitioning, see the
Logical Partitioning Information in the
iSeries Service Functions
.
5341
Secondary partition not running at optimum.
Check the primary partition Product Activity Log for system memory
entries from approximately the same time. Perform the actions indicated
for those entries. For more information on Logical Partitioning, see the
Logical Partitioning Information in the
iSeries Service Functions
.
5342
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system processor
entries from approximately the same time. Perform the actions indicated
for those entries. For more information on Logical Partitioning, see the
Logical Partitioning Information in the
iSeries Service Functions
.
5343
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system memory
errors from approximately the same time. Perform the actions indicated for
those entries.
For more information on Logical Partitioning see the Logical Partitioning
Information in the
iSeries Service Functions
.
B6xx (including A6xx)
274
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference