Failing Item
Description
Document Description
GXC7777
Electrical interference
GXC8888
Other workstation on port is failing
GXC9999
Error occurred with pass-through command
GXCBBBB
Too many devices are active on the workstation
IOP
GXCEEEE
Active device turned off
GXCLINK
Communications network equipment
UXCFF00
User suspected problem
(B2xx) Logical Partition Reference Codes
The code that logically partitions the system detected an error in the logical
partition. These reference codes are posted in the Partition Status screens under the
SST/DST
Work with system partitions
option.
1.
Characters 3 and 4 of word 1 are the partition ID of the logical partition with
the problem.
2.
Find the unit reference code in the following table.
For more on the Failing Item column entries, see Logical Partition Failing Items
Details, which follows the reference code table below.
Table 1. (B2xx) Logical Partition Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
1210
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information about logical partitions.
See the
iSeries Service Functions
information.
Look in the Primary partition’s Service Action Log for a B6005090 during
the secondary partition IPL. Use that SRC and go to RCT.
If you do not find a B6005090 in the Service Action Log of the Primary
partition then look for any SRC which was logged during the IPL of the
Primary partition. Search the Service Action Log first and if you do not
find an SRC there then search the Product Activity Log. Use the new SRC
and go to RCT.
1220
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. Read and understand the information about logical partitions.
See the
iSeries Service Functions
information.
Initiate a Primary partition main storage dump then contact your next level
of support.
1230
A problem occurred during the IPL of a secondary partition
The partition ID is characters 3 and 4 of the B2xx reference code in word 1
of the SRC. See the
iSeries Service Functions
information.
This is a partitioning configuration problem. The partition is lacking the
necessary resources to IPL. Refer the customer to their software support.
B075
System Reference Codes