Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
2333
Power Supply P03 ID is Invalid
2334
Power Supply P04 ID is Invalid
2400 to 2402
UPS Enable/Disable Failure
2403
UPS CPM Failure
2404
UPS Battery Failure
2405
UPS Unit Failure
2406 to 2407
UPS Enable/Disable Failure
2410 to 2411
UPS Test Failure
2413
UPS Interface Failure
2600
Power Good Fault
2601 to 2604
Power Good Fault
2610
Processor/Memory Card not installed
2611
Processor Regulator fault
2612
Optical Converter 5V Fault
The SPCN detected a fault on the SPCN card optical converter 5V.
2613
Configuration Requires 200V Input
Configuration now requires 200V AC power.
300E
EPO Circuit Fault
The ac module installed in the 9406 Expansion Unit (FC 504x) detected a
fault in the UEPO signal. The signal was active and the incoming ac
voltage was still present.
TWRCARD
21F9362
21F5680
302B
PCC Overcurrent
The power control compartment is causing an over current condition in the
9406 Expansion Unit power system.
Exchange the ac module and the SPCN port cable at the same time.
TWRCARD
21F5680
21F9631
21F9362
3100
I2C Bus Controller Communication fault
3101
I2C Bus 1 Communication fault
3102
I2C Bus 2 Communication fault
1xxx
32
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)