The following gives background information regarding processor / memory SRC
formats and control panel functions.
Collect data from Functions 11, 12, and 13 of the system panel, or words 1 through
9 from the Main Store Dump (MSD) screen. This SRC, beginning with
″
B4
″
, may
contain up to five FRUs. Eight characters of this data represent a single FRU. The
FRU characters have two parts: a unit reference code, and a type number. The type
number is usually a CCIN. If the number is 0000, either the fix will involve
software, or the CCIN for the failed hardware cannot be determined without using
the procedure to which you will be directed. The location of this data is shown
below:
PANEL FUNC 11:
B4xx____
RC01TP01
RC02RC03
RC04RC05
PANEL FUNC 12:
DATA0012
DATA0013
TP02TP03
TP04TP05
PANEL FUNC 13: DATA0016
DATA0017
DATA0018
DATA0019
The FRU information for FRU 1 would be RC01 and TP01, for FRU 2 would be
RC02 and TP02, etc.
Characters
Description / Meaning
Length
RC01
FRU 1 - Ref Code
4 Characters
TP01
FRU 1 - Type
4 Characters
RC02
FRU 2 - Ref Code
4 Characters
TP02
FRU 2 - Type
4 Characters
RC03, TP03, RC04, TP04, RC05, TP05 same as above.
DATA012, DATA013,
DATA016, DATA017,
DATA018, DATA019
Miscellaneous Data - Not applicable, but
may be needed for your next level of
support.
8 Characters
The example below shows relevant data for three FRUs:
RC01=4300, TP01=244A, RC02=8200, TP02=2884, RC03=8100, TP03=2884,
the remaining values are zeroes.
PANEL FUNC 11:
B427____
4300244A
82008100
00000000
PANEL FUNC 12:
xxxxxxxx
xxxxxxxx
28842884
00000000
PANEL FUNC 13:
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
Characters
Description / Meaning
Length
4300
FRU 1 - Ref Code = 4300
4 Characters
244A
FRU 1 - Type = 244A
4 Characters
8200
FRU 2 - Ref Code = 8200
4 Characters
2884
FRU 2 - Type = 2884
4 Characters
8100
FRU 3 - Ref Code = 8100
4 Characters
2884
FRU 3 - Type = 2884
4 Characters
B428, B448
244
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference