Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
6907
High Speed Link (HSL) I/O bridge failure
LIC detected invalid data in the HSL I/O bridge VPD. The bridge and HSL
loop may not have become operational.
For this reference code the failing item list presented in the
″
Service Action
Log
″
can be different from the failing item list documented here. That is
due to the differences in system models and features installed.
If the
″
Service Action Log
″
is available then use the failing item list
presented there for servicing this reference code.
If the
″
Service Action Log
″
is not available then use the failing item list
documented here. By following the procedures in the symbolic FRUs listed
here you will isolate to the correct FRU list based on system model and
features installed.
NOTE: A fiber optic cleaning kit may be required for optical HSL
connections.
6908
High Speed Link (HSL) I/O bridge failure
LIC data in the I/O bus vpd could not be accessed. The I/O Bus identified
in the SRC may not have become operational.
If there is a B600 6906 reference code, close this problem in the SAL and
work the 6906 error.
For this reference code the failing item list presented in the
″
Service Action
Log
″
can be different from the failing item list documented here. That is
due to the differences in system models and features installed.
If the
″
Service Action Log
″
is available then use the failing item list
presented there for servicing this reference code.
If the
″
Service Action Log
″
is not available then use the failing item list
documented here. By following the procedures in the symbolic FRUs listed
here you will isolate to the correct FRU list based on system model and
features installed.
NOTE: A fiber optic cleaning kit may be required for optical HSL
connections.
B6xx (including A6xx)
System Reference Codes
277