Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
5005
Service program failed
The workstation adapter system console failed to respond.
Perform WSAC-PIP1.
FI00320
FI00602
UG3USR1
AJDG301
FI00380
5007
Service program failed
The workstation adapter console failed to respond.
If the system uses an
iSeries
Operations Console, perform OPCON-PIP1.
Otherwise, perform WSAC-PIP1.
FI00320
FI00602
UG3USR1
AJDG301
FI00380
5008
DST console failed to respond
Perform Operations Console-PIP3.
5010
IPL service function ended abnormally
Perform LIC-PIP4.
AJDG301
5082
DST lost contact with the console
A service program lost contact with the system console.
Do you have a twinaxial terminal for the console?
No
Yes
↓
Perform TWSC-PIP1.
Perform WSAC-PIP1.
AJDG301
UG3USR1
5083
IPL service function ended abnormally
A service program lost contact with the system console.
Perform TWSC-PIP1.
AJDG301
UG3USR1
5090
System startup failed in unattended IPL mode
Perform the following:
v
If reference code A6005090 is displayed on the control panel for more
than 10 minutes, perform LIC-PIP11.
v
For reference code B6005090, perform LIC-PIP11.
FI00580
FI00500
FI00301
FI00021
FI00065
AJDG301
5092
System is in DASD migration mode
“Install Licensed Internal Code” and “Upgrade Load Source” was specified
but the key is not in the manual position. Change the key position to
manual and perform a system IPL.
5094
IASP detected a failure during the vary on operation
Perform LIC-PIP12.
50FF
DST unrecoverable program error
Perform LIC-PIP3.
AJDG301
FI00380
B6xx (including A6xx)
System Reference Codes
271