Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
7300
AC Module Over current
The ac module or one of the feature power supplies reported an over
current condition.
Perform SPCN-PIP10.
7400
Control Supply fault
A control supply fault was reported in the ac module.
7401
Control Supply over current
A control supply over current condition was detected in the ac module.
7402
Control Supply 5V regulator fault
The SPCN detected a fault in the +5 V dc regulator of the control supply in
the ac module.
7403
Control Supply 12V regulator fault
The SPCN detected a fault in the +12 V dc regulator of the control supply
in the ac module.
7404
Control Supply 12V regulator over current
An over current condition was detected in the +12 V dc regulator of the
control supply in the ac module.
Perform SPCN-PIP10.
7407
Optical Converter 5V Fault
The SPCN detected a fault on the SPCN card optical converter 5V.
90H6287
SPNLCRD
7500 to 7503
Air Moving Device missing error
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed. Install Air Moving Device if
missing, replace if already installed.
7610
Air Moving Device Fault
The Air Moving Device is operating at the wrong speed.
7611
Air Moving Device missing error
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed. Install Air Moving Device if
missing, replace if already installed.
7620
Air Moving Device Fault
The Air Moving Device is operating at the wrong speed.
7621
Air Moving Device missing error
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed. Install Air Moving device if
missing, replace if already installed.
7630
Air Moving Device Fault
The Air Moving Device is operating at the wrong speed.
1xxx
44