Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
7201
Power Supply over current fault
The ac module reported an over current condition. This is usually caused
by one of the regulators.
Perform SPCN-PIP10.
7202
Power Supply over current fault
Feature power supply 2 reported an over current condition. This is usually
caused by one of the regulators.
Perform SPCN-PIP10.
7203
Power Supply over current fault
Feature power supply 1 reported an over current condition. This is usually
caused by one of the regulators.
Perform SPCN-PIP10.
7300
AC Module Over current
The ac module or one of the feature power supplies reported an over
current condition.
Perform SPCN-PIP10.
7400
Control Supply fault
A control supply fault was reported in the ac module.
7401
Control Supply over current
A control supply over current condition was detected in the ac module.
7402
Control Supply 5V regulator fault
The SPCN detected a fault in the +5 V dc regulator of the control supply in
the ac module.
7403
Control Supply 12V regulator fault
The SPCN detected a fault in the +12 V dc regulator of the control supply
in the ac module.
7404
Control Supply 12V regulator over current
An over current condition was detected in the +12 V dc regulator of the
control supply in the ac module.
Perform SPCN-PIP10.
7405
Control Supply 5VSW Regulator Fault
7406
Control Supply 5VSW power off failure
This failure must be corrected before removing powered VPDPART to
avoid damage.
7407
Optical Converter 5V Fault
The SPCN detected a fault on the SPCN card optical converter 5V.
90H6287
SPNLCRD
7410 to 7411
AC Module Failure
1xxx
System Reference Codes
107