Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
9029
Incorrect hardware configuration change has been detected.
Contact your next level of support.
902F
Array addendum Product Activity Log entry
This entry contains additional array information for 90xx reference codes
when the array contains more than 10 members. Use the 90xx entry that
occurred at the same time as this reference code as the starting point for
this problem.
9030
Array no longer protected due to missing or failed disk unit
Perform SDIOP-PIP21.
9031, 9040
Array protection temporarily suspended
No action required. Protection will be automatically restarted.
9041
Background array parity check detected and corrected errors
Call your next level of support to report the problem.
AJDGP01
9050
Required cache data cannot be located for a disk unit.
Perform SDIOP-PIP23.
9051
IOP cache data exists for a missing or failed device.
If all configured units are missing, a 9054 reference code may appear in the
product activity log. If so, perform the action indicated for the 9054
reference code.
Otherwise, perform SDIOP-PIP27.
9052
Cache data exists for device that has been modified.
Perform SDIOP-PIP28.
9053
IOP resources not available due to previous problems.
Take action on other IOP reference codes which have surfaced.
If you cannot get to SST or DST, and cannot perform a type A or B IPL,
perform a type D IPL from removable media. Look for Product Activity
Log entries for other IOP reference codes and take action on them.
9054
IOP resources not available due to previous problems.
Power off the system and remove all new or replacement disk units. IPL
the system to DST. If you cannot perform a type A or B IPL, perform a
type D IPL from removable media.
Look for Product Activity Log entries for other IOP reference codes and
take action on them.
9081
I/O processor card detected device error
9082
I/O processor card detected device error
Perform SDIOP-PIP16.
FI01105
STORIOA
FI01140
BACKPLN
FI01106
2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C, 286D, 286E, 286F, 5702
152
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)