Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0902
Power Supply P03 powered off for concurrent maintenance
0903
Power Supply P04 powered off for concurrent maintenance
0904
Power Supply P05 powered off for concurrent maintenance
0905
Power Supply P06 powered off for concurrent maintenance
0F0F
AC Module Failure
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F12
Undefined box ID, EEPROM test failed
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F13
Undefined box ID, Code type mismatch
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F1F
Undefined box ID, LCD test failed
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2C
Unknown box ID
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2D
Unknown box ID, Code level mismatch.
The SPCN node cannot determine the machine type of the box in which it
is installed.
TWRCARD
BACKPLN
21F9429
0F2E
SPCN Network Fault
The box ID is not defined. A network communications failure occurred.
TWRCARD
BACKPLN
21F9429
102B
PCC Overcurrent
The power control compartment is causing an over current condition in the
FC 5032 Removable Storage Unit power system.
The ac module and the SPCN port cable should be exchanged together.
TWRCARD
21F5680
21F5793
21F9362
1510
Detected AC loss
Before replacing any parts, verify that the AC input voltage is correct.
1511
Power supply failure
1512
Power supply failure
1513 to 1514
Power supply failure
1516
No Power Supplies Present
The required power supplies are not installed.
1520
Detected AC loss
Before replacing any parts, verify that the AC input voltage is correct.
1xxx
System Reference Codes
27