Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
3300
Storage unit detected a media problem
Perform SDIOP-PIP1.
3400
I/O processor card detected device error
NOTE: If external devices are attached check EXTSCSI and DEVTERM first.
FI02112
STORIOA
FI01106
DEVTERM
FI01140
3401
Device backplane problem
3501
I/O processor Licensed Internal Code error
AJDGP01
IOP
3600 to 3601
System log entry only, no service action required
6070
A permanent I/O processor failure occurred
6071
I/O processor Licensed Internal Code error
AJDGP01
6072
I/O processor Licensed Internal Code error
AJDGP01
IOP
6073
IPL device not ready
6075
I/O processor resource not available
AJDGP01
6076
I/O processor card detected media error
6081 to 6083
I/O processor Licensed Internal Code error
AJDGP01
IOP
6085
I/O processor Licensed Internal Code error
AJDGP01
IOP
MA_BRDG
6200
A permanent IOA hardware error occurred
6201
IOA LID is not valid
AJDGP01
6602
An I/O processor Licensed Internal Code error occurred.
AJDGP01
8000
A permanent IOP or cache adaptor card failure occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs
one at a time in the order shown.
8002
A permanent cache adaptor card failure occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs
one at a time in the order shown.
8004
Voltage drop detected on I/O processor 5 volt power supply.
8005
A recoverable IOP or cache adaptor card error occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs
one at a time in the order shown.
8007
A recoverable cache adaptor card error occurred.
Note:
DO NOT replace both FRUs at the same time. Exchange the FRUs
one at a time in the order shown.
2749, 2767, 2768, 2842, 2843, 2844, 284B, 284C, 284D, 284E, 286C, 286D, 286E, 286F, 5702
System Reference Codes
149