Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
7711
Air Moving Device BP1 Not Present
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed. Install Air Moving device if
missing, replace if already installed.
7720
Air Moving Device BP2 Fault
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed or operating at the wrong
speed.
7721
Air Moving Device BP2 Not Present
A problem was detected with an Air Moving Device which can be caused
by an Air Moving Device not being installed. Install Air Moving device if
missing, replace if already installed.
7730
Air Moving Device BP1 Fault
7731
Air Moving Device BP1 Not Present
7740
Air Moving Device BP2 Fault
7741
Air Moving Device BP2 Not Present
8001
A Battery Power Unit 1 Failed
A response was received from battery power unit 1 charger that was not
valid.
46G3890
ACMODUL
BACKPLN
8002
Battery Power Unit 2 Failed
A response was received from battery power unit 2 charger that was not
valid.
46G3890
ACMODUL
BACKPLN
8101
A Battery Power Unit 1 Failed
Battery power unit 1 capacity test failed.
46G3890
8102
Battery Power Unit 2 Failed
Battery power unit 2 capacity test failed.
46G3890
8110
Battery Power Unit 1 and 2 Failed
Replace both batteries.
8201
A Battery Power Unit 1 Failed
Battery power unit 1 charging fault was detected.
46G3890
8202
Battery Power Unit 2 Failed
Battery power unit 2 charging fault was detected.
46G3890
8301
A Battery Power Unit 1 Failed
Battery power unit 1 load test fault occurred.
46G3890
8302
Battery Power Unit 2 Failed
Battery power unit 2 load test fault occurred.
46G3890
8400
No VPD Found due to Invalid Bypass
1xxx
System Reference Codes
109