Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
E000
WS IOP or IOA error during working operation
AJLYD01
FI00610
F000
WS IOP or IOA operating system program error
AJLYD01
FI00719
Table 2. Failing Items Details
Failing Item
Description
Document Description
AJDG301
OS/400 licensed program
Service Functions; APAR or LICTR
AJDGP01
LIC - Input/Output Processor Licensed Internal
Code
Service Functions; APAR or LICTR
AJLYD01
Work Station IOP or IOA system Licensed
Internal Code
Service Functions; APAR or LICTR
CAUPDT
Device Licensed Internal Code change
Communications Configuration
GAU7777
Electrical interference
GAU8888
Other work station on port is failing
GAU9999
Error occurred with pass-through command
GAUBBBB
Too many work stations are active on the
workstation IOP
GAUDMCC
Device Licensed Internal Code change
GAUEEEE
Active device turned off
MAUFFFF
Magnetic stripe
Refer to I/O device service information
UAUFF00
User suspected problem.
(B075) Workstation Adapter Console Reference Codes
The workstation adapter console detected a failure.
1.
Look at characters 5 through 8 of the top 16 character line of function 11 (4
rightmost characters of word 1). These 4 characters are the unit reference code.
2.
Find the unit reference code in the following table.
For more on the Failing Item column entries, see Table 2. Workstation Adapter
Console Failing Items Details, which follows the reference code table below.
Table 1. (B075) Workstation Adapter Console Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0101
WS IOP detected error when transmitting data
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
0103
WS IOP detected parity error from device
Perform WSAC-PIP1.
FI00601
GXC7777
FI00631
FI00730
B070
220
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)