Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
6718
Regulator fault
Regulator 1 reported a fault.
Fault tolerance may allow continued system operation.
671A
Regulator fault
6738
Regulator fault
Regulator 2 reported a fault.
Fault tolerance may allow continued system operation.
673A
Regulator fault
Regulator 18 reported a fault.
Fault tolerance may allow continued system operation.
6758
Regulator fault
Regulator 3 reported a fault.
Fault tolerance may allow continued system operation.
6818
One of the regulators has reported a fault
A fault detection failure occurred for a regulator. The regulator or the ac
module/SPCN card can cause this fault.
6918
One of the regulators has reported a fault
An over current fault detection failure occurred for a regulator. The
regulator or the ac module/SPCN card can cause this fault.
6A18
Regulator Fault
A regulator fault detection failure occurred for regulator 1. The ac module
or the regulator can cause this fault.
6A38
Regulator Fault
A regulator fault detection failure occurred for regulator 2. The regulator or
the ac module/SPCN card can cause this fault.
6A58
Regulator Fault
A regulator fault detection failure occurred for regulator 3. The regulator or
the ac module/SPCN card can cause this fault.
6B00
Disk Unit 1 regulator fault
The regulator that powers disk unit 1 reported a fault.
6B01
Disk Unit 2 regulator fault
The regulator that powers disk unit 2 reported a fault.
6B02
Disk Unit 3 regulator fault
The regulator that powers disk unit 3 reported a fault.
6B03
Disk Unit 4 regulator fault
The regulator that powers disk unit 4 reported a fault.
1xxx
System Reference Codes
99