Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
FFFE
Read data error: tape path dirty
This error may be caused by a dirty recording head, poor or damaged
tapes, worn or damaged data cartridges, or using a format that is not
correct.
1.
Switch off power to the tape unit.
2.
Switch on power to the tape unit.
3.
Clean the recording head in the tape unit. Use the IBM Cleaning
Cartridge Kit (part 21F8593).
4.
Visually inspect the data cartridge. If it is damaged, discard it.
5.
Check the lifetime statistics on the system for this tape volume ID. If
the cartridge has a history of tape errors, discard it.
If the data on the tape was not written by an AS/400 system, the format
may not be correct.
Do not use the cleaning cartridge more than 12 times.
Each data cartridge must have a unique volume ID label. The user must
assign a volume ID when the tape is initialized (INZTAP).
MLVTMED
91F0914
FFFF
Write data error: tape path dirty
This error may be caused by a dirty recording head, poor or damaged
tapes, worn or damaged data cartridges, or using a format that is not
correct.
1.
Switch off power to the tape unit.
2.
Switch on power to the tape unit.
3.
Clean the recording head in the tape unit. Use the IBM Cleaning
Cartridge Kit (part 21F8593).
4.
Visually inspect the data cartridge. If it is damaged, discard it.
5.
Check the lifetime statistics on the system for this tape volume ID. If
the cartridge has a history of tape errors, discard it.
If the data on the tape was not written by an AS/400 system, the format
may not be correct.
Do not use the cleaning cartridge more than 12 times.
Each data cartridge must have a unique volume ID label. The user must
assign a volume ID when the tape is initialized (INZTAP).
MLVTMED
91F0914
Table 2. Model 002 Tape Drive Failing Items
Failing Item
Description
Document Description
42F7300
Fan
7208 8mm Tape Drive service information
53F3861
Internal signal cable
7208 8mm Tape Drive service information
81F9128
Power supply
7208 8mm Tape Drive service information
91F0721
Terminating plug
7208 8mm Tape Drive service information
91F0914
Tape drive
7208 8mm Tape Drive service information
AJEDA00
I/O processor Licensed Internal Code
Service Functions; APAR or LICTR
MLVTMED
Defective tape
7208 8mm Tape Drive service information
7208
System Reference Codes