SRC
What You Should Do
11 B6xx xxxx
The Licensed Internal Code detected a failure.
1.
Look at characters 5 through 8 of the top 16 character
line of function 11 (4 rightmost characters of word 1).
These 4 characters are the unit reference code.
2.
See the table below and find the unit reference code.
3.
When working with the Product Activity Log, system
LIC entries often occur as a secondary effect of other
hardware related entries. The following list is a
suggested method of isolating these kinds of
problems.
a.
Examine the date and time of the informational
reference codes.
b.
Determine if any other reference codes were
logged at or before the same date and time.
c.
Start the service approach based on these other
logged errors.
For more on the Failing Item column entries, see Licensed Internal Code (LIC)
Failing Items Details, which follows the reference code table below.
Table 1. (B6xx) Licensed Internal Code (LIC) Reference Codes
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0000
Operating system status code
This reference code is for information only. It is shown in the Product
activity log as a side effect of a condition that was detected by LIC.
Normally, no action should be taken as a result of information reference
codes. However, to isolate the root cause, use these suggestions:
1.
Examine the date and time of the informational reference code.
2.
Determine if any other reference codes have been logged at or before
the same date and time.
3.
Begin the service approach based on these other logged errors.
0102
A machine check occurred during IPL
Words 2 to 9 of this SRC contain additional diagnostic information. Record
SRC words 1 through 9 before attempting to IPL again and report the
problem to your Software Service Provider.
0103
Main storage dump must be copied for service.
Perform LIC-PIP1.
0104
Terminate Immediate reference code is bad
Perform LIC-PIP8.
AJDG301
0105
More than one request to terminate the system was issued
Perform LIC-PIP8.
AJDG301
0106
Terminate Immediate data is not valid
Perform LIC-PIP8.
AJDG301
B6xx (including A6xx)
System Reference Codes
263