Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
6118
Regulator over current fault
One of the regulators detected an over current condition. This may be
caused by the regulator or one of cards powered by the regulator.
6218
Regulator over current fault
Regulator 1 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6238
Regulator over current fault
Regulator 2 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6258
Regulator over current fault
Regulator 3 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6318
Regulator Fault
Regulator 1 has reported a fault.
631A
Regulator Fault
Regulator 1 has reported a fault.
6338
Regulator Fault
Regulator 2 reported a fault.
633A
Regulator Fault
Regulator 2 reported a fault.
6358
Regulator Fault
A regulator 3 reported a fault.
6400 to 6401
Power Good Fault
6518
One of the regulators has reported a fault
An over current sensor failure occurred for a regulator. The ac module or
one of the regulators can cause this fault.
6618
Regulator over current fault
Regulator 1 reported a false over current condition.
Fault tolerance may allow continued system operation.
6638
Regulator over current fault
Regulator 2 reported a false over current condition.
Fault tolerance may allow continued system operation.
6658
Regulator over current fault
Regulator 3 reported a false over current condition.
Fault tolerance may allow continued system operation.
1xxx
98