Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
C002
SCSI selection or reselection timeout occurred
FI00870
FI01106
FI01112
MEDIA
FI01140
FI01141
DEVTERM
CDTRAY
C010
Undefined sense key returned by device
C020
Device internal configuration error
C100
SCSI bus command error occurred
FI00870
FI01106
FI01112
MEDIA
FI01140
FI01141
DEVTERM
CDTRAY
C110
SCSI command timeout occurred
FI00870
FI01106
FI01112
MEDIA
FI01140
FI01141
DEVTERM
CDTRAY
C210
Unexpected device condition recovered
The device successfully recovered from a temporary error.
No action is required. This reference code is logged for information only.
C300
Media or device error occurred
Perform the following:
1.
Clean the disk.
2.
Attempt the failing operation again.
3.
If this does not correct the problem, exchange the failing items.
C301
Media or device error occurred
Dust check encountered. Optical media and/or drive’s optical lens is dirty.
Clean the optical drive and the media contained in the drive.
C302
Media or device error occurred
While writing to the media, an ’out of spare sectors’ condition was
encountered. The media can no longer be written to but is still readable.
Clean the optical drive and the media contained in the drive.
632x, 6330, 6336
System Reference Codes
175