Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
0336
The data format is incorrect; the tape cannot be read
The tape format is not known or not compatible. The data cartridge may
not have been recorded on an AS/400 system.
Get another copy of the data cartridge recorded in a format and density
given support by the AS/400 system.
ML2TMED
46G2227
46G3934
42F7300
0337 to 0338, 033D Tape unit detected a read error on the tape medium
Perform the Action for reference code 030B.
ML2TMED
46G2227
46G3934
42F7300
0395 to 0397, 039D
to 039F
Tape unit detected a write error on tape medium
Perform the Action for reference code 030B.
ML2TMED
46G2227
03AE, 03B0
Tape unit detected a read or write error on tape medium
Perform the Action for reference code 030B.
ML2TMED
46G2227
03B3 to 03B4
Tape unit detected a write error on tape medium
Perform the Action for reference code 030B.
ML2TMED
46G2227
03B5
Tape unit detected a read error on the tape medium
Perform the Action for reference code 030B.
ML2TMED
46G2227
0417 to 0419, 0458,
045A, 0467 to
0468, 046D, 0498
to 049A, 049C,
04A1 to 04A8,
04AB to 04AD,
04FA, 04FC to
04FD
Tape unit failure
The tape drive reported a hardware error to the IOP; the amber light on
the tape drive may be blinking.
Perform TU-PIP2.
46G2227
ML2TMED
46G3934
42F7300
3002
I/O processor addressed the tape unit; no response
The tape drive did not respond to commands from the IOP. Perform the
following:
1.
Ensure that the system interface cable is connected.
2.
Ensure that power is on.
If the above items are correct, perform the following:
1.
2.
46G2227
46G3934
FI00830
FI00141
46G2599
17G1500
42F7300
3004
Tape unit failed after Licensed Internal Code was loaded
The tape drive does not respond to IOP commands after new Licensed
Internal Code was transferred to the tape drive.
Perform TU-PIP4.
46G2227
7208
System Reference Codes
187