background image

 

 

 

 

 100 Crossing Boulevard

Framingham, MA 01702-5406 USA

www.nmscommunications.com

Installing the Vision VS 5000 
Server 

9000-62672-10 

Summary of Contents for Vision VS 5000

Page 1: ...100 Crossing Boulevard Framingham MA 01702 5406 USA www nmscommunications com Installing the Vision VS 5000 Server 9000 62672 10 ...

Page 2: ...d the Sun logo are trademarks or registered trademarks of Sun Microsystems Inc in the United States and or other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the United States and or other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc Linux is a register...

Page 3: ...o a T1 network 10 Chapter 4 Cabling the server 11 Connecting to the serial management ALOM port 12 Prerequisites 12 Connecting the server s Ethernet interface 14 Connecting VS 5000 Servers for redundancy 15 Connecting signaling link trunk cables 17 Chapter 5 Compliance information 19 Compliance statements 19 EU R TTE statement 19 FCC Part 15 Class A statement 19 FCC Part 68 statement 20 Canadian I...

Page 4: ......

Page 5: ...ng the Vision VS 5000 Server this document R TTE Declaration of Conformity RoHS Declaration of Conformity Software License Agreement You must provide a crossover Ethernet cable if you are connecting two Vision VS 5000 servers for redundancy support For more information refer to Connecting VS 5000 Servers for redundancy on page 15 Rear panel The following illustration shows the Vision VS 5000 Serve...

Page 6: ... 1 In a web browser enter the following URL http www nmscommunications com docs 2 Select Signaling Server from the list of products 3 Select Signaling Server VS 5000 Release 1 A list of Vision Signaling Server manuals displays 4 Select the manual that you want to Download View or Print 5 Enter the following password at the prompt vs0925 You can then download view or print the manual ...

Page 7: ...RIAL MGT 0 1 PS1 PCI0 PCI1 PCI2 PCI LOCK DOWN ALARM 0 1 3 2 SS7 signaling link trunk connectors SS7 signaling link trunk LEDs SS7 signaling link trunk connectors and LEDs There is one green LED for each SS7 signaling link The signaling link LEDs provide the following indications LEDs Description Off Trunk is not configured Slow blinking green Loss of signal Fast blinking green Loss of frame or los...

Page 8: ...ing table describes the functionality of each LED LED Description LINK ACT Status of the Ethernet link When the Ethernet link has established link integrity the LED is on and steady It also indicates the transmitting and receiving activity on the link When activity is present on the Ethernet link the LED flickers 100 Data rate of the Ethernet link When the LED is on the data rate is 100 Mb When th...

Page 9: ...he Vision VS 5000 Server chassis Only technically qualified personnel should perform service and maintenance tasks Avoid injury Lifting the server chassis and attaching it to the rack is a two person job If needed use an appropriate lifting device A fully loaded Vision VS 5000 Server not including the mounting brackets weighs approximately 16 53 kg 36 40 lbs Caution Temperature The operating tempe...

Page 10: ...ncy on page 15 7 Connect device signaling link trunk interfaces For information refer to Connecting signaling link trunk cables on page 17 Once installation is complete configure the Vision VS 5000 Server as described in the Vision Signaling Server Configuration and Administration Manual For information about accessing this manual refer to Accessing Vision documentation on page 6 Connecting to a T...

Page 11: ...munications 11 4 4 Cabling the server This topic describes how to connect the following interfaces Serial management ALOM port Server s Ethernet interface Two servers for redundancy Signaling link trunk cables ...

Page 12: ...Pin 4 Ground Pin 3 Transmit Data Pin 2 Data Terminal Ready Pin 1 Request to Send Pin 1 Pin 8 If you need to connect to the serial management ALOM port using a cable with a DB 9 connector use the adapter shipped with the server to perform the crossovers given for each connector The RJ 45 to DB 9 adapter is wired as described in the following table Serial port RJ 45 connector DB 9 adapter Pin Signal...

Page 13: ...ber truths Laptop running terminal emulator NET MGT SERIAL MGT 0 1 PS1 PCI0 PCI1 PCI2 PCI LOCK DOWN ALARM 0 1 3 2 Serial management RJ 45 connector ALOM 2 Log in at the console prompt Reconfigure the server IP address host name DNS server and time zone You can also configure this server to be a member of a redundant pair at this point For information about configuring the server IP address refer t...

Page 14: ... the two VS 5000 Servers must be connected to the IP network to communicate with each other This does not need to be a private link NET MGT SERIAL MGT 0 1 PS1 PCI0 PCI1 PCI2 PCI LOCK DOWN ALARM Ethernet 0 0 1 3 2 Ethernet RJ 45 connectors The following illustration shows the pinout of each of the RJ 45 interfaces Pin 8 Transmit Receive Data 3 Pin 7 Transmit Receive Data 3 Pin 6 Transmit Receive Da...

Page 15: ... The following illustration shows the pinouts of the 10 100Base T Ethernet RJ 45 connectors Pins 4 5 7 and 8 are grounded through a spark gap for 100Base T Ethernet connections LINK ACT LED 100 LED Pin 1 Pin 8 Pin 1 T Transmit to network Pin 2 R Transmit to network Pin 3 T1 Receive from network Pin 4 Ground Pin 5 Ground Pin 6 R1 Receive from network Pin 7 Ground Pin 8 Ground The Ethernet connector...

Page 16: ...pin assignments for this crossover cable Side A Side B 1 3 2 6 3 1 4 7 5 8 6 2 7 4 8 5 The following illustration shows how to set up two Vision VS 5000 Servers as a redundant pair Backup Vision VS 5000 Server Primary Vision VS 5000 Server SS7 links on DS1 trunks Private Ethernet connection Ethernet 1 Ethernet 1 ...

Page 17: ...ess Trunk 1 Trunk 2 or both Trunk 1 and Trunk 2 connect a shielded T1 or E1 RJ 48 cable to one or both 8 pin modular jacks To access all four trunks use the two trunk adapter cables NMS P N 32851 Each trunk adapter cable separates the 8 pin modular jack on the end bracket into two RJ 48C connectors The following illustration shows the trunk adapter cable NMS RJ 45 Length 4 RJ 48C Jack 1 3 Jack 2 4...

Page 18: ......

Page 19: ...its for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio co...

Page 20: ...h ESF bipolar with eight zero substitution B8ZS no line power 100 ohms 04DU9 1SN 6 0N RJ 48C If the equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required If advance notice is not practical the telephone company will notify you as soon as possible Also you will be advised of your right to file a compl...

Page 21: ...nal Equipment Technical Requirements documents The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users must ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection Repairs to certified equipment must be ...

Page 22: ...ork To learn what approvals you require contact the appropriate regulatory authority in the target country EMC Country Standard US FCC Part 15 Class A with shielded Telecom cables and STP Ethernet cables Canada IECS 003 with shielded Telecom cables and STP Ethernet cables EU EN55022 1998 A1 2000 A2 2003 Class A EN55024 1998 A1 2001 A2 2003 with shielded Telecom cables and STP Ethernet cables Safet...