INSTALLATION 

GUIDE 

(v. 2.1) 

Summary of Contents for Dixell XWEB300

Page 1: ...INSTALLATION GUIDE v 2 1 ...

Page 2: ......

Page 3: ...ce The last version available can be downloaded from our internet website WARNING This instructions manual describes common functionalities for XWEB300D XWEB500D XWEB500 unless otherwise specified Hereby instructions refer to firmware version 2 1 or previous WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required ...

Page 4: ... 4 23 Contents 1 CHECK LIST 5 2 RS485 CONNECTION 6 The TTL output 8 Serial address of the instruments 8 3 MODEM CONNECTION or point to point connection 9 4 INTRANET ETHERNET CONNECTION 19 5 INTERNET CONNECTION 20 6 TROUBLESHOOTING GUIDE 22 7 UNIT SETUP REMINDER 23 ...

Page 5: ...l find XWEB 1 CD Rom with manual and accessory softwares 2 Power cord 3 Installation Quick Guide 4 Before proceeding setting up a modem connection please check the modem is approved by Dixell Dixell cannot be held responsible for damages or missuse with other devices Connect RS485 line to XWEB with provided plug Connect your PC to XWEB with provided RJ45 cross cable Proceed executing configuration...

Page 6: ... on two polarised terminals Please pay respect to the right sequence for all the devices connected to the serial line Follow these important instructions The RS485 serial line must reach all the instruments where they are installed Make sure of the wire polarities when screwing them into the instrument terminals The cable must have 2 or 3 wires with shield minimum section 0 5mm2 eg the BELDEN 8772...

Page 7: ...uency sources Do not connect shield to ground Do not connect the Gnd ground terminal Remember to draw a map of the line This will help you to find errors if something is wrong The instrument with RS485 have and terminals respect the polarity To keep the line balanced it is necessary a 100 Ohm resistor at the end of the line you can use the RS 485 and RS 485 terminals of the last instrument connect...

Page 8: ...connected with a TTL cable to the instrument with TTL compatibility Serial address of the instruments Each instrument must be defined by its unique address Check the address into the Adr parameter value of each instruments Take reference to the instruction manual of the instrument itself to find the right procedure to enter the programming and set the value The easiest way to work with the categor...

Page 9: ...rnet internet is not available It is strongly advised to use a dedicated telephone line IMPORTANT Use exclusively modem devices approved by Dixell Remember that many modems are not compatible with Linux The list of compatible models can be found under the menu Configuration System Modem In Windows XP you will use the New Connection Wizard 1 From the Start menu select Control Panel ...

Page 10: ...1592028150 XWEB300D_500_500D stp GB r2 1 2012 06 22 doc XWEB500 10 23 ...

Page 11: ... doc XWEB500 11 23 2 If Control Panel is set for Classic View double click on the Network Connections icon 3 If Control Panel is set for Category View select the Network and Internet Connections category then double click on the Network Connections icon ...

Page 12: ...1592028150 XWEB300D_500_500D stp GB r2 1 2012 06 22 doc XWEB500 12 23 4 Under Network Tasks select Create a new connection ...

Page 13: ...1592028150 XWEB300D_500_500D stp GB r2 1 2012 06 22 doc XWEB500 13 23 5 Click Next ...

Page 14: ...00D stp GB r2 1 2012 06 22 doc XWEB500 14 23 6 Click Next at the bottom of this page to continue with the setup instructions 7 Select Connect to the Internet and click Next 8 Select Set up my connection manually and click Next ...

Page 15: ...1592028150 XWEB300D_500_500D stp GB r2 1 2012 06 22 doc XWEB500 15 23 9 Select Connect using a dialup modem and click Next 10 Type XWEB 500 DIRECT MODEM in the ISP Name box and click Next ...

Page 16: ... Phone Number box E G If telephone number is 555789 and area code is 099 put this Telephone number 099555789 If there is a switching machine and you have to dial a digit to get the line 0 or 9 for example it depends on the switching machine put this telephone number 0 099555789 or 9 099555789 Click Next ...

Page 17: ...l in the User Name box Type dialup password dixell in the Password and Confirm Password boxes We recommend that you check the first 2 checkboxes but not the 3rd box which turns on the Internet Connection Firewall Click Next 13 Place a tick in the box to create a shortcut on your desktop and click Finish ...

Page 18: ...T MODEM connection automatically when you start Internet Explorer do the following Start Internet Explorer and select Internet Options from the Tools menu Select the Connections tab Make sure that XWEB 500 DIRECT MODEM is your default connection if not highlight it and click Make Default Make sure that the Always dial my default connection option is selected ...

Page 19: ...ach the Server This number is an example of what you should expect http 192 168 000 111 After receiving the address from your network Administrator the XWEB 500 must be set with this number The Intranet method allows the connection to interact with XWEB 500 from all the PC Clients Insert the net address assigned by the administrator into the Browser address bar Bookmark the address with personalis...

Page 20: ...me for the future connections Ask your provider for more details about the rent of a the static IP This the internet system requirements for the best result Wide band connection At least 1 static IP address for the XWEB The internet connection is established through a device called Router that receives and sends the data as interface between an Intranet and Internet The Provider also assigns the a...

Page 21: ...sed for SSH connection While the ports on the WAN side are Telnet to configure the router from a remote also via Internet HTTP To access the XWEB 500 If working with the router GATEWAY and DNS check your Internet contract details Depending on your network topology you may need a reverse NAT on port 80 It is not enough to link port 80 on the router side to port 80 on intranet side Some firewall or ...

Page 22: ...re to the caps lock button an capitol letters Is it your password correct My browser can t reach XWEB 500 log in page Check cable typology From windows go to Start Run ping 192 168 0 150 t A continuous set of information should be appear Someone in the intranet LAN receive a warning message about an IP conflict XWEB uses the same address of a resource already used in your intranet LAN Change XWEB ...

Page 23: ...__________ DNS 2 ___________________________ SMTP ___________________________ E mail Address ___________________________ Modem ___________________________ Telephone number ___________________________ Notes ________________________________________________________________ ________________________________________________________________ ________________________________________________________________...