Check whether your package contains following items:
■ Industrail Serial Server x 1 or
Industrial Modbus Gateway x 1 or
Industrial Modbus Concentrator x 1 or
Industrial Protocol Gateway x 1
■ Hardware Installation Guide with Warranty Card
■ 3-Pin 5.08mm Terminal Block
■ 3-Pin 5.08mm Lockable Terminal Block (DC models only)
■ RJ-45 to Male DB9 cable
■ AC Power Cord (EU / US models only)
■ Foot Rubbers
■ Rack Mount Kit
*SE/MB/PG5908A has its serial ports 9-16 covered up compared to SE/MB/PG5916
Open Main Menu or go back one level higher
Scroll up
Scroll down
Confirm the selection. When working with IP addresses,
pressing <SEL> means moving to the next digit
LCM Display
■
The openings to the sides are for the devices heat dissipation. Please never
obstruct or cover them with any objects.
■
The device server’s factory IP by default is 10.0.50.100. You can access the
device by its WebUI once it is connected to a physical network or use Serial
Manager, for more information on Serial Manger, please refer to the user manual.
Please be aware that the PC needed for this procedure needs to be in the same
subnet, or you may refer yourself to the device’s manual on Web UI configuration.
1.
Ground the device properly. If you are using the AC model, you can use the
grounding screw next to the AC inlet. Else, if you are using the DC model, you can
use the FG pin in the terminal block. It is required to connect to the grounds at all
times to ensure overall maximum performance.
2.
If you opt to place the device on a rack, your will need to secure the rack mounts
kit on to the device before placing it on the rack. If you opt to place the device on
a surface, you can put on the foot rubbers to prevent the device from sliding.
3. You can then choose whether to plug in the I/O ports at this point or do it later. Next
you can then proceed to connect the device to the LAN (switch or PC), take care
on using the RJ-45 connector; after this proceed to the device’s settings.
Serial and RJ-45 Connectors
* The isolated models do not have DTR/DSR available
Ethernet
Tx+
Tx-
Rx+
Rx-
-
-
-
-
RTS
DTR
TXD
RXD
SG
SG
DSR
CTS
-
Tx-
Tx+
Rx+
SG
SG
Rx-
-
-
-
-
Data+
SG
SG
Data-
-
RS-232
RS-422/
4-Wire RS-485
2-Wire
RS-485
Serial and Male DB9 Connectors
* This cable (RJ-45 to Male DB9) is included in the package.
RS-232
DB9
1
-
-
-
2
RXD
RXD+
Data+
3
TXD
TXD+
-
4
DTR
TXD-
-
5
SG
SG
SG
6
DSR
RXD-
Data-
7
RTS
-
-
8
CTS
-
-
9
-
-
-
RS-422/
4-Wire RS-485
2-Wire
RS-485
1
6
9
5
Buttons