2.
On the global navigation tab, click Server.
3.
On the Category pane, click Correlation.
The items of the Category pane change into the items concerning the correlation management.
4.
On the Category pane, click End to End View (Hyper-V).
5.
On the Main pane, check the target server checkbox to register as a Hyper-V host.
6.
On the Action pane, click Register/Reload under Hyper-V Host.
The information input screen is displayed.
7.
Based on the information that was backed up in "
6.1.2.1 Manual Backing Up Operational Environment
", after entering the
necessary information, click Confirm.
6.2 Upgrading Storage Cruiser's Manager (for Solaris, Linux)
6.2.1 Upgrading on Non-clustered Systems
6.2.1.1 Preparing for Upgrade
Point
It is recommended that you back up the system before starting the upgrade. If a failure occurs during the upgrade, you cannot restore
the environment to the pre-installation status (rollback).
When returning back to the state before installation of the upgrade, recover (restore) the system from the backup.
6.2.1.1.1 Backing Up Operational Environment of Previous Version
With the following procedure, back up the operational environment of the previous version:
1.
Back up the following information manually.
-
Performance monitoring
If the performance monitoring was performed with the previous version, refer to the following information related to the
performance monitoring with Web Console of the previous version and record the configuration information of the previous
version.
-
Interval that obtains performance information (in seconds)
-
Performance monitoring target (only for ETERNUS Disk storage system. Minimum LUN_V, Maximum LUN_V)
-
VMware vCenter Server configuration information
If VMware vCenter Server was registered in the Storage Cruiser's manager of the previous version, record the configuration
information of the previous version with the following procedure:
1.
Log in to Web Console.
2.
On the global navigation tab, click Server.
3.
On the Category pane, click Correlation.
The items of the Category pane change into the items concerning the correlation management.
4.
On the Category pane, click End to End View (VMware).
The VMware End to End view list is displayed in the Main pane.
5.
Record the IP address and the port number of VMware vCenter Server that are displayed in the Main pane.
2.
Back up the operation environment of the previous version of the Storage Cruiser's manager.
Refer to "
A.33 Capacity Necessary for Backup of Previous Version
" for information on the capacity required to perform a backup.
a.
Login to the server on which to perform the tasks. Perform operations after logging in with root (superuser).
- 57 -