4.
Execute the following silent installation command.
For
installLogFile
, specify the file in which to output installation log with an absolute path. It is optional to specify for
installLogFile
.
dvdromDrive:\Agent_windows\Storage_Cruiser\windows_x86\scagtsilentinstall.bat [-l
<installLogFile>]
Point
-
If nothing is specified for
installLogFile
, an install log file named " scagtsilentinstall.log" is created in the working directory
specified by the environment variable TEMP.
-
If there is any file of the same name as the specified install log file, it is overwritten.
-
It is required to specify an existing directory with write permission for the directory in which to store the install log file. If it
has no write permission, no error message is output in the command prompt or screen and the process terminates with error.
-
If the path name of the installation log file contains any spaces, they should be surrounded by double quote characters.
-
The characters " | : * ? / . < > % & ^ ; ! are not supported for path name of the installation log file.
Note
-
If an invalid option is specified, its corresponding error message is output in the install log file and the process exits. No error
message is output in the command prompt or screen.
-
Do not execute multiplexly the command for silent installation. If it is multiplexly executed, the command executed after
that terminates abnormally. At this time, an install log file is not created.
-
During an update, it is not possible to specify an installation parameter file for the command. In the case that a file has been
specified, the command terminates in an error.
5.
On completion of installation, a command prompt is displayed.
Eject the DVD-ROM.
7.3.3.2 Confirming Results of Upgrade with Silent Installation
Check the return value from the silent installation command. If necessary, check the install log file. However, if the return value from
the silent installation command is 3 or 9, an install log file is not created. For details, refer to "Return Values for Silent Installation (for
Storage Cruiser's Agent)" in the
ETERNUS SF Installation and Setup Guide
.
The installation result can be viewed in the install log file, too.
Open the install log file to see "ResultCode" in the ResponseResult section. In "ResultCode" is written the return value from the silent
installation command.
Point
If the upgrade was terminated abnormally, refer to "
11.3.3 In Case of Problem During Upgrade of Storage Cruiser's Agent (for
" to recover the system to the normal state.
7.3.4 Tasks to Be Performed After Upgrade
Perform the following procedure:
Note that in these tasks, in addition to operations with the Managed Server, there are operations to execute from Web Console.
- 109 -