Function
Code
Parameter
Name
Setting Range
Default
Property
P5.37
S1 delay time 0.0s ~ 3600s
0.0s
★
P5.38
S valid mode
selection 1
0:High level valid
1:Low level valid
Unit's digit: FWD
Ten's digit: REV
Hundred's digit: S1
Thousand's digit:S2
Ten thousand's digit:S3
00000
★
P5.39
S valid mode
selection 2
0:High level valid
1:Low level valid
Unit's digit:S4
0
★
Group P6: Output Terminals
P6.00
M01 terminal
output mode
1:Switch signal output (M01)
0
☆
P6.01
M01 function
0: No output
1: AC drive running
2:Fault output (stop)
3: Frequency-level detection FDT1 output
4: Frequency reached
5: Zero-speed running(no output at stop)
6: Motor over1oad pre-warning
7: AC drive overload pre- warning
8: Set count value Reached
9: Designated count value reached
10: Length reached
11: PLC cycle complete
12: Accumulative running time reached
13: Frequency limited
14: Torque limited
15: Ready for RUN
16: FIV>FIC
17: Frequency upper limit reached
18: Frequency lower limit reached (no output et stop)
19: Under voltage state output
20: Communication setting
21: Reserved
22: Reserved
23: Zero-speed running 2 (having output at stop)
24: Accumulative power-on time reached
25: Frequency level detection FDT2 output
26: Frequency 1 reached
27: Frequency 2 reached
28: Current 1 reached
29: Current 2 reached
30: Timing reached
31: FIV input limit exceeded
32: Load becoming 0
0
☆