98
Elmark Automatyka S.A.
ul. Niemcewicza 76, 05-075 Warszawa, tel. (+48) 22 773 79 37; [email protected]; www.elmark.com.pl
NIP: 5252072585; KRS: 0000803828, Sąd Rejonowy dla M-St. Warszawy, XIV Wydział Gosp. KRS; Kapitał Zakładowy 525.000 zł, w pełni opłacony
Function
Code
Parameter
Name
Setting Range
Default
Property
P1.06
Startup DC
braking time/ Pre-
excited time
0.0s ~ 100.0s
0.0s
★
P1.07
Acceleration/
Deceleration
mode
0: Linear acceleration/ deceleration
1: S-curve acceleration/ deceleration A
2: S-curve acceleration/ deceleration B
0
★
P1.08
Time proportion
of S-curve start
0.0% ~ (100.0%-P1.09)
30.0%
★
P1.09
Time proportion of
S-curve end
0.0% ~ (100.0%-P1.08)
30.0%
★
P1.10
Stop mode
0: Decelerate to stop
1: Coast to stop
0
☆
P1.11
Initial frequency of
stop DC braking
0.00Hz ~ maximum frequency
0.00Hz
☆
P1.12
Wailing time of
stop DC braking
0.0s ~ 100.0s
0.0s
☆
P1.13
Stop DC braking
current
0% ~ 100%
0%
☆
P1.14
Stop DC braking
time
0.0s ~ 100.0s
0.0s
☆
P1.15
Brake use ratio 0%-100%
100%
☆
Group P2: Motor Parameters
P2.00
Motor type
selection
0: Common asynchronous motor
1: Variable frequency
asynchronous motor
0
★
P2.01
Rated motor
power
0.1kW ~ 30.0kW
Model
dependent
★
P2.02
Rated motor
voltage
1V ~ 2000V
Model
dependent
★
P2.03
Rated motor
current
0.01A ~ 655.35A
Model
dependent
★
P2.04
Rated motor
frequency
0.01Hz ~ maximum frequency
Model
dependent
★
P2.05
Rated motor
rotational speed
1rpm ~ 65535rpm
Model
dependent
★
P2.06
Stator resistance
(asynchronous
motor)
0.001Ω ~ 65.535 Ω
Model
dependent
★
P2.07
Rotor resistance
(asynchronous
motor)
0.001Ω ~ 65.535 Ω
Model
dependent
★
P2.08
Leakage inductive
reactance
(asynchronous
0.01mH ~ 655.35mH
Model
dependent
★
P2.09
Mutual inductive
reactance
(asynchronous
motor)
0.1mH ~ 6553.5mH
Model
dependent
★