Group PP: User-Defined Function Codes
PP.00
User password
Default
0
Setting Range
0 ~ 65535
If it is set to any non-zero number, the password protection function is enabled. After a password has been set and taken effect,
you must input the correct password in order to enter the menu. If the entered password is incorrect you cannot view or modify
parameters. If PP.00 is set to 00000, the previously set user password is cleared, and the password protection function is disabled.
PP.01
Restore default settings
Default
0
Setting Range
0
No operation
1
Restore factory settings except motor parameters
2
Clear records
1: Restore default settings except motor parameters
If FP-01 is set to 1, most function codes are restored to the default settings except motor parameters, frequency reference decimal
point (P0.22, fault records, accumulative running time (P7.09), accumulative power-on time (P7.13) and accumulative power
consumption (P7.14).
2: Clear records
If PP.01 is set to 2, the fault records, accumulative running time (P7.09), accumulative power-on time (P7.13) and accumulative
power consumption (P7.14) are cleared.
Group C0: Torque Control and Restricting Parameters
C0.00
Speed/Torque control selection
Default
0
Setting Range
0
Speed control
1
Torque control
It is used to select the AC drive's control mode: speed control or torque control.
The ED2000 provides S terminals with two torque related functions, fTorque control prohibited (function 29 )and Speed
control/Torque control switchover (function 46). The two S terminals need to be used together with C0.00 to implement speed
control/torque control switchover.
If the S terminal allocated with function 46 (Speed control/Torque control switchover) is OFF, the control mode is determined by
C0.00. If the S terminal allocated with function 46 is ON, the control mode is to reverse the value of C0-00.
However, if the torque control prohibited terminal is ON, the AC drive is fixed to run in the speed control mode.
C0.01
Torque setting source in torque control
Default
0
Setting Range
0
Digital setting (C0.03)
1
FIV
2
FIC
3
Reserved
4
PULSE setting
5
Communication setting
6
MIN (FIV,FIC)
7
MAX (FIV,FIC)
C0.03
Torque digital setting in torque control
Default
150%
Setting Range
-200.0% ~ 200.0%
C0.01 is used to set the torque setting source. There are a total of eight torque setting sources. The torque setting is a relative
value. 100.0% corresponds to the AC drive's rated torque. The setting range is -200.0% to 200.0%, indicating the AC drive's
maximum torque is twice of the AC drive's rated torque.