Address definition of communication parameters
This part is the content of the communication, used to control the operation of the inverter, inverter status and related parameters
setting. Read and write functional code parameter (some function code which can not be changed, only for the use of
manufacturers or monitoring) : function code parameter address label rules:
By function block number and the label for the parameter address representation rules .High byte: F0-FF(P group),A0-AF(C
group),70-7F(D group)low byte:00-FF
Such as:P3.12,The address is expressed as F30C; attention: PF group: Neither read the parameters, and do not change parameters;
Group D group: only can read, do not change the parameters.
When some parameters in inverter is in operation, do not change; Some parameters of the inverter in any state, cannot be
changed; Change function code parameters, but also pay attention to the range of parameters, units, and related instructions.
In addition, because the EEPROM is stored frequently, the service life of the block can reduce the life of the block EPROM, so some
function code under the mode of communication, do not need to be stored, just change the value of RAM. If it is P group of
parameters, in order to realize the function, as long as putting this function code address high F into 0 can be achieved. If it is C
group of parameters, in order to realize the function, as long as putting the function code the address of high A into 4 can be
achieved. Corresponding function codes are shown as the following address: the high byte: 00 - OF (P group), 40 - 4F(group B) low
byte: 00 to FF
Such as:
Function code P3.12 is not stored in the EEPROM, The address is expressed as 030C;Function code C0-05 is not stored in the
EEPROM, The address is expressed as 4005; The address representation can only do writing RAM. can't do reading action. when
reading.it is invalid address. For all the parameters, can also use the command code 7H to implement this function.
Stopping/starting parameters:
Parameter address
Parameter description
1000
Communication Setting value (-10000 ~ 10000)
(decimal system)
1001
Operating frequency
1002
Bus voltage
1003
output voltage
1004
current output
1005
output power
1006
output torque
1007
running velocity
1008
S Input Flag
1009
M01 output Flag
100A
FIV voltage
100B
FIC voltage
100C
Reserved
100D
count value input
100E
The length of the input
100F
The load speed
1010
PIO setting
1011
PIO feedback
1012
PLC steps
1013
PULSE the input pulse frequency unit 0.01kHz
1014
Reserved
1015
The remaining running time
1016
FIV before correction voltage
1017
FIC before correction voltage
1018
Reserved
1019
Linear velocity