Group P2: Motor Parameters
P2.00
Motor type selection
Default
0
Setting Range
0: Common asynchronous motor
1: Variable frequency asynchronous motor
P2.01
Rated motor power
Default
Model dependent
Setting Range
0.1kW ~ 30.0kW
P2.02
Rated motor voltage
Default
Model dependent
Setting Range
1V ~ 2000V
P2.03
Rated motor current
Default
Model dependent
Setting Range
0.01A ~655.35A
P2.04
Rated motor frequency
Default
Model dependent
Setting Range
0.01Hz ~Maximum frequency
P2.05
Rated motor rotational
speed
Default
Model dependent
Setting Range
1rpm ~65535rpm
Set the parameters according to the motor's nameplate no matter whether V/F control or vector control is adopted. To achieve
better V/ F or vector control performance, motor auto-tuning is required. The motor auto-tuning accuracy depends on the correct
setting of motor nameplate parameters.
P2.06
Stator resistance (asynchronous motor)
Default
Model dependent
Setting Range
0.001Ω
-
30.000Ω
P2.07
Rotor resistance (asynchronous motor)
Default
Model dependent
Setting Range
0.001Ω
-
65.535 Ω
P2.08
Leakage inductive reactance
(asynchronous motor)
Default
Model dependent
Setting Range
0.01mH ~ 655.35mH
P2.09
Mutual inductive
reactance (asynchronous motor)
Default
Model dependent
Setting Range
0.1mH ~6553.5mH
P2.10
No-load current (asynchronous motor)
Default
Model dependent
Setting Range
0.01A-P2.03
The parameters in P2.06 to P2.10 are asynchronous motor parameters.
P2.06-- P2.10 parameters are ordinary unavailable on the motor's nameplate and are obtained by means of inverter's auto-tuning.
Asynchronous motor's stationary auto-tuning can obtain only P2.06 to P2.08 three parameters .Asynchronous motor's dynamic
auto tuning can obtain besides all
the parameters in P2.06 to P2.10,and can also obtain encoder phase sequence and current
loop Pl.
Each time "Rated motor power" (P2.01) or "Rated motor voltage" (P2.02) is changed, the AC drive automatically restores values
of P2.06 to P2.10 to the parameter setting for the common standard Y series asynchronous motor.
If it is impossible to perform asynchronous motor's stationary auto tuning manually input the values of these parameters
according to data provided by the motor manufacturer.
P2.11-P2.36 Reserved
P2.37
Auto-tuning selection
Default
0
Setting Range
0
No auto-tuning
1
Asynchronous motor static auto-tuning
2
Asynchronous motor complete auto-tuning